If you plan to use a non-ABB high-output motor or an IP23 motor, consider these additional
requirements for protecting the motor insulation and bearings in drive systems:
•
If motor power is below 350 kW: Equip the drive and/or motor with the filters and/or
bearings according to the table below.
•
If motor power is above 350 kW: Consult the motor manufacturer.
Requirement for
Nominal AC supply
voltage
ABB du/dt and common mode filters, insulated N-
end motor bearings
Motor insulation system
100 kW < P
n
< 350 kW or
IEC 315 < frame size <
IEC 400
P
n
< 100 kW or frame size
< IEC 315
134 hp < P
n
< 469 hp or
NEMA 500 < frame size <
NEMA 580
P
n
< 134 hp or frame size
< NEMA 500
+ N or CMF
+ N or CMF
Standard:
Û
LL
= 1300 V
U
n
≤ 420 V
+ N + d
u
/d
t
+ CMF
+ d
u
/d
t
+ (N or CMF)
Standard:
Û
LL
= 1300 V
420 V <
U
n
< 500 V
or
+ N or CMF
+ N or CMF
Reinforced:
Û
LL
= 1600 V,
0.2 microsecond rise time
+ N + d
u
/d
t
+ CMF
+ d
u
/d
t
+ (N or CMF)
Reinforced:
Û
LL
= 1600 V
500 V <
U
n
≤ 600 V
or
+ N + CMF
+ N or CMF
Reinforced:
Û
LL
= 1800 V
+ N + d
u
/d
t
+ CMF
+ N + d
u
/d
t
Reinforced:
Û
LL
= 1800 V
600 V <
U
n
≤ 690 V
+ N + CMF
+ N + CMF
Reinforced:
Û
LL
= 2000 V,
0.3 microsecond rise
time
1)
1) If the intermediate DC circuit voltage of the drive is increased from the nominal level due to long term resistor braking
cycles, check with the motor manufacturer if additional output filters are needed.
Additional note for sine filters
A sine filter also protects the motor insulation system. The peak phase-to-phase voltage
with a sine filter is approximately 1.5 ·
U
n
.
78 Guidelines for planning the electrical installation
Содержание ACS880-37LC-0390A-7
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 37LC drives Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 13: ...16 Resistor braking Further information Table of contents 13 ...
Страница 14: ...14 ...
Страница 24: ...24 ...
Страница 28: ...28 ...
Страница 50: ...50 ...
Страница 70: ...70 Mechanical installation ...
Страница 110: ...10 110 Electrical installation ...
Страница 113: ...With FDPI 02 modules OPEN TERMINATED 1 1 2 2 OPEN TERMINATED 3 Electrical installation 113 11 ...
Страница 134: ...134 ...
Страница 140: ...140 ...
Страница 148: ...a b c 148 Maintenance ...
Страница 151: ...4 5 6 Maintenance 151 ...
Страница 164: ...164 ...
Страница 174: ...174 ...
Страница 196: ...196 ...
Страница 199: ... Dimension drawing examples ACS880 37LC 0390A 7 with main contactor Dimensions 199 ...
Страница 201: ...ACS880 37LC 1270A 7 with common motor terminal cubicle Dimensions 201 ...
Страница 202: ...ACS880 37LC 1940A 7 with common motor terminal cubicle 202 Dimensions ...
Страница 205: ...Location and size of input terminals Contact ABB for details Dimensions 205 ...
Страница 206: ... 100 kA input cubicle option F274 206 Dimensions ...
Страница 208: ...Inverter module cubicle with two R8i modules bottom cable exit 208 Dimensions ...
Страница 209: ...Inverter module cubicle with three R8i modules bottom cable exit Dimensions 209 ...
Страница 210: ...Brake chopper cubicle 210 Dimensions ...
Страница 211: ... Units with common motor terminal cubicle H359 Cubicle width 300 mm bottom cable exit Dimensions 211 ...
Страница 212: ...Cubicle width 300 mm top cable exit 212 Dimensions ...
Страница 213: ...Cubicle width 400 mm bottom cable exit Dimensions 213 ...
Страница 214: ...Cubicle width 400 mm top cable exit 214 Dimensions ...
Страница 215: ...Cubicle width 600 mm bottom cable exit Dimensions 215 ...
Страница 216: ...Cubicle width 600 mm top cable exit 216 Dimensions ...
Страница 238: ...238 ...
Страница 240: ...240 ...