![ABB ACS880-1604 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/abb/acs880-1604/acs880-1604_hardware-manual_2645060.webp)
60 Guidelines for planning electrical installation
Selecting the energy storage
WARNING!
ABB is not responsible for the customer ‘s energy storage selection or
protection of the energy storage.
The customer must equip the DC/DC converter with a suitable energy storage system.
Parallel DC/DC converters can have a common energy storage:
•
Dimension the energy storage so that it withstands the required current cycles and the
stored energy is sufficient. Take the depth of discharge into account in energy storage
lifetime calculations.
•
The energy storage must withstand the current ripple of the converter. See
page
•
The output voltage (energy storage voltage) is not allowed to exceed the DC/DC
converter DC bus voltage. Add sufficient voltage margin in the design to prevent this in
case of voltage dips or grid faults.
•
The recommended energy storage operating voltage is:
U
storage
= 150 V … 80% of
U
DC
•
The DC voltage values of the drives are:
•
with diode supply units with modules (ACS880-304 +A003, ACS880-304 +A018):
•
with IGBT supply units with modules (ACS880-204) typically
•
with regenerative rectifier units with modules (ACS880-904):
•
where
•
We recommend to measure the energy storage voltage. If you use a super capacitor
as the energy storage, voltage measurement is obligatory. If the converter is equipped
with the optional BAMU voltage/current measurement unit, the converter measures its
output voltage (and thus also the energy storage voltage) automatically. You do not
need any additional measurement for the converter. If there is no BAMU, you must
arrange the voltage measurement separately, and send the measured value to the
converter control program, eg, via a fieldbus communication (if in use), or by some
other means. For more information, see section
Energy storage voltage measurement
and estimation
and parameter description in
ACS880 DC/DC converter control
program firmware manual
(3AXD50000024671 [English]).
•
The energy storage must have a disconnecting device and contactor. See
Disconnection of energy storage at the storage end
and
U
DC
= 1.35 ×
U
AC
U
DC
= 1.41 ×
U
AC
(can be changed with supply unit parameter group 123 DC
volt ref)
U
DC
= 1.35 ×
U
AC
U
DC
=
Drive DC voltage (in the DC bus)
U
AC
=
Drive input voltage (AC)
Содержание ACS880-1604
Страница 1: ...ABB industrial drives Hardware manual ACS880 1604 DC DC converter modules ...
Страница 4: ......
Страница 12: ...12 ...
Страница 36: ...36 Operation principle and hardware description ...
Страница 45: ...Cabinet construction 45 Kits for DDC R8i unit in 800 mm Rittal TS 8 enclosure ...
Страница 46: ...46 Cabinet construction Stage 1 Installation of common parts ...
Страница 47: ...Cabinet construction 47 Stage 2 Module and bottom cable entry installation parts ...
Страница 48: ...48 Cabinet construction Stage 3 Busbars and quick connectors for connecting DDC module and filter ...
Страница 49: ...Cabinet construction 49 Stage 4A DC connection with charging ...
Страница 50: ...50 Cabinet construction Stage 4B DC connection without charging ...
Страница 51: ...Cabinet construction 51 Stage 5A DC connection with charging ...
Страница 52: ...52 Cabinet construction Stage 5B DC connection without charging ...
Страница 53: ...Cabinet construction 53 Stage 6 DDC and energy storage connection ...
Страница 54: ...54 Cabinet construction Stage 7 Control unit mounting plate ...
Страница 55: ...Cabinet construction 55 Stage 8 DDC shroud installation ...
Страница 56: ...56 Cabinet construction Stage 9 DDC module and filter installation ...
Страница 58: ...58 Cabinet construction Kits for DDC R8i unit in 800 mm wide generic enclosure ...
Страница 64: ...64 Guidelines for planning electrical installation ...
Страница 71: ...Electrical installation 71 5 Refit any shrouding removed earlier and close the cubicle doors 4 a b b ...
Страница 80: ...80 Electrical installation ...
Страница 97: ...Maintenance 97 7 3 4 5 6 ...
Страница 99: ...Maintenance 99 3 4 5 6 7 8 9 9 ...
Страница 102: ...102 Maintenance 12 Install and tighten the two screws 10 11 12 ...
Страница 108: ...108 Maintenance 6 6 6 7 5 4 ...
Страница 109: ...Maintenance 109 8 9 8 ...
Страница 112: ...112 Maintenance 4 4 ...
Страница 113: ...Maintenance 113 6 6 5 7 7 8 ...
Страница 170: ...170 Dimension drawings R8i DC DC converter module ...
Страница 171: ...Dimension drawings 171 ...
Страница 172: ...172 Dimension drawings Quick connectors of the DC DC converter module ...
Страница 173: ...Dimension drawings 173 Quick connectors Dimensions in mm 1 mm 0 0394 in ...
Страница 174: ...174 Dimension drawings BDCL filter module ...
Страница 176: ...176 Dimension drawings BCU control unit ...
Страница 177: ...Dimension drawings 177 BAMU voltage current measurement unit ...
Страница 179: ...Dimension drawings 179 Ramp Dimensions in mm 1 mm 0 0394 in ...
Страница 180: ...180 Dimension drawings Dimensions in mm 1 mm 0 0394 in ...
Страница 181: ...Dimension drawings 181 Internal cabinet fan W2E 143 AA09 01 W2E 143 AA15 01 Air flow ...
Страница 185: ...Dimension drawings 185 Charging controller BSFC 02C SWITCH FUSE CONTROLLER 79 3 11 247 9 72 66 5 2 62 ...
Страница 190: ...190 Dimension drawings ...
Страница 194: ...194 Example circuit diagrams ...
Страница 222: ...www abb com drives www abb com drivespartners 3AXD50000023642 Rev B EN 2017 02 08 Contact us ...