![ABB ACS880-07 Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/abb/acs880-07/acs880-07_hardware-manual_2997048.webp)
•
section
Powering the heating and lighting equipment (oG300, +G301 and
•
circuit diagrams delivered with drive for the actual wiring.
■
Cabinet lighting (G301)
This option contains LED lighting fixtures in each cubicle (except joining and brake resistor
cubicles) and a 24 V DC power supply. The lighting is powered from the same external
110…240 V AC power source as the cabinet heater (G300).
■
Terminals for external control voltage (G307)
The option provides terminals for connecting external uninterruptible control voltage to the
control unit and control devices when the drive is not powered.
See also sections:
•
Supplying power for the auxiliary circuits (page 91)
•
Connecting a 230/115 V AC auxiliary voltage supply (UPS, G307) (page 104)
•
circuit diagrams delivered with drive for the actual wiring.
■
Output for motor space heater (G313)
The option contains:
•
load switch for providing electrical isolation during service
•
miniature circuit breaker for overcurrent protection
•
terminal block for external supply and heating element(s) connection
The heater is off when the drive is running. The customer controls the heating elements in
the motor windings on and off with the external supply. The power and voltage of the motor
heater depend on the motor.
See also sections:
•
Supplying power for the auxiliary circuits (page 91)
•
Powering the heating and lighting equipment (oG300, +G301 and
+G313) (page 107)
•
circuit diagrams delivered with drive for the actual wiring.
■
Supply connection by busbars (G317)
This option provides input (supply) terminals and a busbar entry that enable direct connection
to busbar trunking systems.
■
Ready/Run/Fault lights (oG327…G329)
These options provide "ready" (+G327, white), "run" (+G328, green) and "fault" (+G329,
red) lights installed on the cabinet door.
■
Halogen-free wiring and materials (G330)
The option provides halogen-free cable ducts, control wires and wire sleeves, thus reducing
toxic fire gases.
■
V-meter with selector switch (G334)
The option contains a voltmeter and a selector switch on the cabinet door. The switch selects
the two input phases across which the voltage is measured.
48 Operation principle and hardware description
Содержание ACS880-07
Страница 1: ...ABB industrial drives Hardware manual ACS880 07 drives 560 to 2800 kW ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 94: ...94 ...
Страница 112: ...Electrical installation 109 5 6 4 3 112 Electrical installation ...
Страница 113: ...110 Electrical installation 7 8 8 Electrical installation 113 ...
Страница 114: ...Electrical installation 111 9 10 114 Electrical installation ...
Страница 116: ...Electrical installation 113 4 5 3 6 7 116 Electrical installation ...
Страница 118: ...2 11 b PE 10 7 5 6 8 a 360 grounding detail 118 Electrical installation ...
Страница 128: ...128 ...
Страница 146: ...146 ...
Страница 148: ...148 ...
Страница 159: ...12 Install and tighten the two M4 12 T20 screws 10 11 12 Maintenance 159 ...
Страница 162: ...6 6a 6a 6b 7a 7b 7 8 8a 8b 162 Maintenance ...
Страница 166: ...166 Maintenance 6 6 7 8 7 166 Maintenance ...
Страница 173: ...6 Reinstall the cover removed earlier and close the cubicle door 4 4 D7T D8T Maintenance 173 ...
Страница 213: ... Dimension drawing examples Frame 2 D7T 2 R8i 12 pulse A004 Dimensions 213 ...
Страница 214: ...Frame 1 D8T 2 R8i IP22 214 Dimensions ...
Страница 215: ...Frame 1 D8T 2 R8i IP54 B055 Dimensions 215 ...
Страница 216: ...Frame 1 D8T 2 R8i with common motor terminal cubicle H359 1 2 216 Dimensions ...
Страница 217: ...Frame 1 D8T 2 R8i with common motor terminal cubicle H359 2 2 Dimensions 217 ...
Страница 218: ...Frame 1 D8T 2 R8i with brake choppers and resistors D150 D151 1 2 218 Dimensions ...
Страница 219: ...Frame 1 D8T 2 R8i with brake choppers and resistors D150 D151 2 2 Dimensions 219 ...
Страница 220: ...Frame 1 D8T 2 R8i with sine output filter E206 1 2 220 Dimensions ...
Страница 221: ...Frame 1 D8T 2 R8i with sine output filter E206 2 2 Dimensions 221 ...
Страница 222: ...Frame 2 D8T 2 R8i 12 pulse A004 with grounding switch F259 222 Dimensions ...
Страница 223: ...Frame 2 D8T 3 R8i 1 2 Dimensions 223 ...
Страница 224: ...Frame 2 D8T 3 R8i 2 2 224 Dimensions ...
Страница 225: ...Frame 2 D8T 3 R8i with common motor terminal cubicle H359 1 2 Dimensions 225 ...
Страница 226: ...Frame 2 D8T 3 R8i with common motor terminal cubicle H359 2 2 226 Dimensions ...
Страница 227: ...Frame 2 D8T 3 R8i with top entry top exit H351 H353 1 2 Dimensions 227 ...
Страница 228: ...Frame 2 D8T 3 R8i with top entry top exit 2 2 228 Dimensions ...
Страница 229: ...Frame 3 D8T 4 R8i 1 2 Dimensions 229 ...
Страница 230: ...Frame 3 D8T 4 R8i 2 2 230 Dimensions ...
Страница 231: ...Frame 3 D8T 4 R8i with common motor terminal cubicle H359 1 2 Dimensions 231 ...
Страница 232: ...Frame 3 D8T 4 R8i with common motor terminal cubicle H359 2 2 232 Dimensions ...
Страница 233: ...Frame 3 D8T 4 R8i with top entry top exit H351 H353 1 2 Dimensions 233 ...
Страница 234: ...Frame 3 D8T 4 R8i with top entry top exit H351 H353 2 2 234 Dimensions ...
Страница 235: ...Frame 4 D8T 5 R8i 6 pulse with top entry exit UL Listed C129 1 2 Dimensions 235 ...
Страница 236: ...Frame 4 D8T 5 R8i 6 pulse with top entry exit UL Listed C129 2 2 236 Dimensions ...
Страница 237: ... Dimensions of empty cubicles options C199 C200 C201 IP22 IP42 Dimensions 237 ...
Страница 238: ...IP54 238 Dimensions ...
Страница 242: ... 600 mm with main breaker bottom cable entry 600 mm with main breaker top cable entry 242 Dimensions ...
Страница 243: ... 1000 mm UL CSA top cable entry Dimensions 243 ...
Страница 244: ... 1000 mm UL CSA bottom cable entry 244 Dimensions ...
Страница 264: ...264 ...
Страница 272: ... 272 ...
Страница 274: ...Contact us www abb com drives www abb com drivespartners 3AUA0000143261 E EN EFFECTIVE 2017 06 05 3AUA0000143261E ...