Maintenance 95
Converter module
Replacing the converter module
WARNING!
Read and follow the instructions in chapter
. Ignoring the instructions can cause physical injury or death,
or damage to the equipment.
Note:
Performing this action requires following accessories that are not included in the
delivery as standard: winch (not available from ABB) and installation stand (order code:
3AUA0000078146).
1. Ensure that the converter is disconnected from the power supply network and all other
precautions described in section
Safety in installation and maintenance
have
been taken into consideration.
2. Disconnect the external control cables from connectors X1 and X2 at the right-hand
side of the cabinet.
3. Remove the shrouds of the cubicle.
4. The cubicles with swing-out frame: remove the screws on the shroud of the swing-out
frame. Open the swing-out frame.
5. Close the inlet and outlet valves of the liquid cooling unit, and drain the cooling circuit
(see
Draining the internal cooling circuit
Note:
Drain and bleed valves
have locking handles. Release the mechanism before turning.
6. Decouple the cooling circuit inlet and outlet pipes from the module: Unscrew the
locking nut until fully open and pull the pipe out.
WARNING!
When re-attaching the coolant hoses, do not
overtighten the outer nuts of the union - leave 2…3 mm
(0.08…0.1 in.) of thread visible. Overtightening will break the
hose.
7. Unplug the fiber optic cables from the module.
8. Disconnect the DC output busbars from the module. Beware not to drop the screws
inside the module!
9. Remove the module mounting screws at top (two at top, two at bottom).
10. Fasten a module installation stand to the frame of the cubicle. For instructions, see
page
11. Pull the module out enough to attach a lifting chain to the front of the module.
12. Pull the whole module onto the installation stand. Keep the pipes and wires away from
the sharp edges and be careful not to damage the coolant inlet.
13. Attach a second lifting chain to the rear of the module. Ensure that the lifting chains
are evenly adjusted.
14. Lift the module onto a pallet or other platform for transportation.
WARNING!
The module is heavy and its centre of gravity is high. The module
topples over easily. Never maneuver it in upright position untied. It is
recommended to lay the module on its side before moving the pallet.
15. Before installing a new module, check and service the quick connector through which
the AC output busbars of the cubicle connect to the module. Clean all contact surfaces
2 mm
Содержание ACS800-67LC
Страница 1: ... ABB WIND TURBINE CONVERTERS ACS800 67LC wind turbine converters Hardware manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 22: ...22 Introduction to the manual ...
Страница 42: ...42 Operation principle and hardware description ...
Страница 52: ...52 Mechanical installation ...
Страница 79: ...Electrical installation 79 3 3 Rotor side cable connection terminals U2 V2 W2 ...
Страница 92: ...92 Maintenance 4 6 5 5 ...
Страница 103: ...Maintenance 103 Bussmann fuses Mersen fuses ...
Страница 109: ...Maintenance 109 5 6 7 ...
Страница 131: ...Technical data 131 Declaration of incorporation ...
Страница 136: ...136 Dimension drawings ACS800 67LC 1075 0575 7 and 1375 0575 7 ...
Страница 137: ...Dimension drawings 137 With 400 mm wide incoming cubicle option C111 ...
Страница 138: ...138 Dimension drawings ACS800 67LC 1375 1125 7 ...
Страница 139: ...Dimension drawings 139 With 400 mm wide incoming cubicle option C111 ...
Страница 140: ...140 Dimension drawings ACS800 67LC 1595 0865 7 and 2035 1125 7 ...
Страница 141: ...Dimension drawings 141 With 400 mm wide incoming cubicle option C111 ...
Страница 143: ...Dimension drawings 143 Options 2H370 and C111 Option 1H371 ...
Страница 144: ...144 Dimension drawings Options 1H371 and C111 Options 2H371 and C111 ...
Страница 145: ...Dimension drawings 145 Option H378 Options H378 and C111 ...
Страница 147: ...Dimension drawings 147 Option 2H372 ...
Страница 148: ...148 Dimension drawings Option 3H372 ...
Страница 149: ...Dimension drawings 149 Option 1H373 ...
Страница 150: ...150 Dimension drawings Option 2H373 ...
Страница 151: ...Dimension drawings 151 Option 3H373 ...
Страница 152: ...152 Dimension drawings Option H375 ...