ACS580-0P Packaged Drive with Disconnect
23
Technical Data
Input Power Connections and Power Connection Terminals
(Supplement to ACS580-01 User’s Manual)
1-Phase 230V
HP ABB Product Code
Drive Input Fuse
Rating
Incoming Power Connections
Ground
Lugs
UL Type
3R /
NEMA 3R
Output Connections to Motor
Amps
(600V)
Bussmann
Type
Minimum
Wire Size
Maximum
Wire Size
Tightening
Torque
(lb/ft)
Minimum
Wire Size
Maximum
Wire Size
Tightening
Torque
(lb/ft)
10
ACS580-0P-075A-2+C192
100
JJS-100
8 AWG
1/0 AWG
4.6
14 AWG -
1/0 AWG
1.6 - 4.1
lb/ft
20 AWG
1 AWG
4
15
ACS580-0P-088A-2+C192
110
JJS-110
4 AWG
300 MCM
16.7
10 AWG
2/0 AWG
5.5
20
ACS580-0P-114A-2+C192
150
JJS-150
4 AWG
300 MCM
16.7
10 AWG
2/0 AWG
5.5
25
ACS580-0P-143A-2+C192
200
JJS-200
4 AWG
300 MCM
16.7
4 AWG
300 MCM
30
30
ACS580-0P-169A-2+C192
250
JJS-250
2 AWG
600 MCM
31.3
3/0 AWG
500 MCM
40
40
ACS580-0P-211A-2+C192
300
JJS-300
2 AWG
600 MCM
31.3
3/0 AWG
500 MCM
40
50
ACS580-0P-273A-2+C192
350
JJS-350
2 AWG
600 MCM
31.3
2x 1/0 AWG 2x 300 MCM 40
NOTE: For information regarding motor terminals, refer to “Drives Power Connection Terminals” in the ACS580-01 Manual
3-Phase 208/230V
HP ABB Product Code
Drive Input Fuse
Rating
Incoming Power Connections
Ground
Lugs
UL Type
3R /
NEMA 3R
Output Connections to Motor
Amps
(600V)
Bussmann
Type
Minimum
Wire Size
Maximum
Wire Size
Tightening
Torque
(lb/ft)
Minimum
Wire Size
Maximum
Wire Size
Tightening
Torque
(lb/ft)
25
ACS580-0P-075A-2+C192
100
JJS-100
8 AWG
1/0 AWG
4.6
14 AWG -
1/0 AWG
1.6 - 4.1
lb/ft
20 AWG
1 AWG
4
30
ACS580-0P-088A-2+C192
110
JJS-110
4 AWG
300 MCM
16.7
10 AWG
2/0 AWG
5.5
40
ACS580-0P-114A-2+C192
150
JJS-150
4 AWG
300 MCM
16.7
10 AWG
2/0 AWG
5.5
50
ACS580-0P-143A-2+C192
200
JJS-200
4 AWG
300 MCM
16.7
4 AWG
300 MCM
30
60
ACS580-0P-169A-2+C192
250
JJS-250
2 AWG
600 MCM
31.3
3/0 AWG
500 MCM
40
75
ACS580-0P-211A-2+C192
300
JJS-300
2 AWG
600 MCM
31.3
3/0 AWG
500 MCM
40
100
ACS580-0P-273A-2+C192
350
JJS-350
2 AWG
600 MCM
31.3
2x 1/0 AWG 2x 300 MCM 40
NOTE: For information regarding motor terminals, refer to “Drives Power Connection Terminals” in the ACS580-01 Manual
3-Phase 460V
HP ABB Product Code
Drive Input Fuse
Rating
Incoming Power Connections
Ground
Lugs
UL Type
3R /
NEMA 3R
Output Connections to Motor
Amps
(600V)
Bussmann
Type
Minimum
Wire Size
Maximum
Wire Size
Tightening
Torque
(lb/ft)
Minimum
Wire Size
Maximum
Wire Size
Tightening
Torque
(lb/ft)
40
ACS580-0P-052A-4+C192
80
JJS-80
8 AWG
1/0 AWG
4.6
14 AWG -
1/0 AWG
1.6 - 4.1
lb/ft
20 AWG
1 AWG
3
50
ACS580-0P-065A-4+C192
90
JJS-90
8 AWG
1/0 AWG
4.6
20 AWG
1 AWG
3
60
ACS580-0P-077A-4+C192
100
JJS-100
8 AWG
1/0 AWG
4.6
20 AWG
1 AWG
3
75
ACS580-0P-096A-4+C192
150
JJS-150
4 AWG
300 MCM
16.7
10 AWG
2/0 AWG
4.1
100
ACS580-0P-124A-4+C192
200
JJS-200
4 AWG
300 MCM
16.7
4 AWG
300 MCM
22.1
125
ACS580-0P-156A-4+C192
225
JJS-225
4 AWG
300 MCM
16.7
3/0 AWG
500 MCM
29.4
150
ACS580-0P-180A-4+C192
300
JJS-300
2 AWG
600 MCM
31.3
3/0 AWG
500 MCM
29.4
200
ACS580-0P-240A-4+C192
350
JJS-350
2 AWG
600 MCM
31.3
2x1/0 AWG 2x 300 MCM 29.4
NOTE: For information regarding motor terminals, refer to “Drives Power Connection Terminals” in the ACS580-01 Manual