10
ACS580-0P 3R Irrigation Packaged Drive
Installation
Installing the Drive (Supplement to ACS580-01 User’s Manual)
WARNING!
Metal shavings or debris in the enclosure can damage electrical equipment and
create a hazardous condition. Where parts, such as conduit plates require
cutting or drilling, first remove the part. If that is not practical, cover nearby
electrical components to protect them from all shavings or debris.
Do not connect or disconnect input or output power wiring, or control wires,
when power is applied.
Never connect line voltage to drive output Terminals T1, T2 and T3.
Do not make any voltage tolerance tests (Hi Pot or Megger) on any part of the
unit. Disconnect motor wires before taking any measurements in the motor or
motor wires.
Make sure that power factor correction capacitors are not connected between
the drive and the motor.
Prepare the Mounting Location
The ACS580 should only be mounted where all of the requirements defined in “Preparing
for Installation” are met.
Mount the Drive
1. Use a hoist to move the cabinet into position.
Note! If the cabinet location does not provide access to the cabinet sides, be
sure to re-mount side panels before positioning cabinet.
2. Install and tighten mounting bolts.