108 Technical data
EMC compatibility and motor cable length
To comply with the EMC limits in the European EMC Directive
(standard IEC/EN 61800-3), use these maximum motor cable
lengths for the 4 kHz switching frequency.
1) Category C1 with conducted emissions only. Radiated emissions are not
compatible when measured with the standard emission measurement setup
and must be measured on cabinet and machine installations for each case.
Notes:
• Remove the EMC screw to disconnect the internal EMC filter.
Refer to
• Radiated emissions are according to C2 with ACS380-042x
drives. For ACS380-040x drives, use a metal enclosure to fulfill
radiated emissions C2 limits with an external EMC filter.
• For 3-phase 380...400 V drives, the maximum motor cable lengths
are according to C3 in the above table with an internal EMC filter.
• For 1-phase and 3-phase 208...240 V drives, the maximum motor
cable lengths are according to the motor cable length table on
page
. The EMC category for these drives is C4 (no EMC).
Frame
size
Maximum motor cable length, 4 kHz
C1
C2
C3
m
ft
m
ft
m
ft
With internal EMC filter (ACS380-042x)
1-phase 208...240 V
R0
-
-
10
30
30
100
R1
-
-
10
30
30
100
R2
-
-
10
30
30
100
3-phase 380...480 V
R0
-
-
10
30
30
100
R1
-
-
10
30
30
100
R2
-
-
10
30
20
66
R3
-
-
10
30
30
100
R4
-
-
10
30
30
100
With optional external EMC filter
1-phase 208...240 V
R0
10
100
50
150
50
150
R1
10
100
50
150
50
150
R2
-
-
50
150
50
150
3-phase 208...240 V/380...480 V
R0
30
100
50
150
50
150
R1
30
100
50
150
50
150
R2
30
100
50
150
50
150
R3
30
100
50
150
50
150
R4
-
-
30
100
50
150
Содержание ACS380 Series
Страница 1: ...ABB MACHINERY DRIVES ACS380 drives Hardware manual...
Страница 4: ......
Страница 12: ...12 Table of contents...
Страница 20: ...20 Safety instructions...
Страница 46: ...46 Mechanical installation...
Страница 60: ...60 Planning the electrical installation...
Страница 86: ...86 Maintenance...
Страница 120: ...120 Technical data...
Страница 122: ...122 Dimension drawings Frame R0 1 phase 230 V...
Страница 123: ...Dimension drawings 123 Frame R0 400 V...
Страница 124: ...124 Dimension drawings Frame R1 230 V...
Страница 125: ...Dimension drawings 125 Frame R1 3 phase 230 V and 3 phase 400 V...
Страница 126: ...126 Dimension drawings Frame R2 230 V...
Страница 127: ...Dimension drawings 127 Frame R2 400 V...
Страница 128: ...128 Dimension drawings Frame R3 400 V...
Страница 129: ...Dimension drawings 129 Frame R4 400 V...
Страница 130: ...130 Dimension drawings...
Страница 138: ...138 Resistor braking...
Страница 169: ...BTAC 02 pulse encoder interface module 169 Dimensions 3AXD50000031154 rev A...
Страница 170: ...170 BTAC 02 pulse encoder interface module...