6.8.7.4
Routing cables in an EXU cabinet with an ED7Y type DCS800 converter
1.
Unscrew the rectangular cover from the DCS800 unit.
Figure 6-40 DCS800 converter (ED7Y)
2.
Connect the two optical fibers to the receptacles of channel CH0 (B)
on the COM-8x circuit board (A) according to the terminal numbers
printed on the marker sleeves.
Figure 6-41 COM-8x circuit board (A) in a DCS800 converter (ED7Y type) and a
detail of channel CH0 (B) on the board
(1) Control panel
(2) Removable cover
1
2
CH0
A
B