194 Parameters
Examples of how the timer configuration defines when the Timer is active are shown below.
0000h…FFFFh
Configuration of timer 1.
1 = 1
Defines the daily start time of timer 1. The time can be
changed in second steps.
The timer can be started at an other time than the start time.
E.g. if the timer's duration is more than one day and the active
session starts during the time, the timer is started at 00:00
and stopped when there is no duration left.
00:00:00
00:00:00…23:59:59 Daily start time of the timer.
1 = 1
No.
Name/Value
Description
Def/FbEq16
Bits of parameter
1 1 1 1 1 1 1 1 1 1 1
0 0 0
Example 1:
Timer is active during the times of the day
defined by other parameters every Weekday and every
Season.
Exception day settings (
…
) do not have any
effect on the Timer.
1 1 1 1 1
0 0 1 1 1 1 0 0 0
Example 2:
Timer is active during the times of the day
defined by other parameters from Mon to Fri, every
Season.
Exception day settings (
…
) do not have any
effect on the Timer.
1 1 1 1 1 0 0 0 0
1
0 0 0 0
Example 3:
Timer is active during the times of the day
defined by other parameters from Mon to Fri, only
during Season 3 (can be configured as eg summer).
Exception day settings (
…
) do not have any
effect on the Timer.
1 1 1 1 1 0 0 1 1 1 1
1 1
0
Example 4:
Timer is active during the times of the day
defined by other parameters from Mon to Fri, every
Season.
In addition, the Timer is active every Exception day
Holidays, regardless what is the day or season.
1 0 1 0 1 0 1 1 1 0 0
1
0
1 Example 5:
Timer is active during the times of the day
defined by other parameters on Mon, Wed, Fri and
Sun, during Season1 and Season 2.
In addition, the Timer is active every Exception day
Workdays, regardless what is the day or season.
1 1 1 1 1 1 1 1 1 1 1
1 0 0 Example 6:
Timer is active during the times of the day
defined by other parameters every Weekday and every
Season.
The Timer is inactive during all Exception days.
M
o
nd
ay
T
ues
da
y
W
e
dn
es
d
ay
T
hur
sd
ay
Fr
id
ay
Sa
tu
rd
ay
S
und
ay
S
eas
on
1
S
eas
on
2
S
eas
on
3
S
eas
on
4
E
xce
pt
io
ns
Ho
lid
a
ys
Wo
rk
da
ys
Содержание ACQ580
Страница 1: ...ABB drives for water Firmware manual ACQ580 pump control program ...
Страница 4: ... 2017 ABB Oy All Rights Reserved 3AXD50000035867 Rev C EN EFFECTIVE 2017 06 21 ...
Страница 29: ...Start up control with I O and ID run 25 After the ID run is completed text Done is shown on row ID run ...
Страница 30: ...26 Start up control with I O and ID run ...
Страница 40: ...36 Default configuration ...
Страница 304: ...300 Parameters ...
Страница 340: ...336 Additional parameter data ...
Страница 422: ...Contact us www abb com drives www abb com drivespartners 3AXD50000035867 Rev C EN 2017 06 21 3AXD50000035867C ...