background image

Cyber security

Product manual 2TMD042000D0009

53

10 

Cyber security

10.1

Disclaimer

The products are designed to be connected and to communicate information and data via a
network interface, which should be connected to a secure network. It is customer‘s sole
responsibility to provide and continuously ensure a secure connection between the product and
customer‘s network or any other network (as the case may be) and to establish and maintain
appropriate measures (such as but not limited to the installation of firewalls, application of
authentication measures, encryption of data, installation of antivirus programs, etc.) to protect
the product, the network, its system and interfaces against any kind of security breaches,
unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB
Ltd and its affiliates are not liable for damages and/or losses related to such security breaches,
unauthorized access, interference, intrusion, leakage and/or theft of data or information.

Although ABB provides functionality testing on the products and updates that we release, you
should institute your own testing program for any product updates or other major system
updates (to include but not limited to code changes, configuration file changes, third party
software updates or patches, hardware change out, etc.) to ensure that the security measures
that you have implemented have not been compromised and system functionality in your
environment is as expected.

Содержание ABB-Welcome M2240-W

Страница 1: ...2TMD042000D0009 10 06 2020 Product manual ABB Welcome M2240 W Video indoor station 4 3 WiFi ...

Страница 2: ... Registering an account on the MyBuildings portal 15 8 2 Download APP 16 8 3 Logging into the APP 17 8 4 Initial setup 18 8 5 Local settings 25 8 5 1 Ringtone setting 25 8 5 2 Volume setting 26 8 5 3 Brightness setting 27 8 5 4 Color setting 28 8 5 5 Contrast setting 29 8 5 6 Language 30 8 5 7 Information 31 8 5 8 Obtaining product manual 32 8 5 9 Restoring to default settings 33 8 5 10 Resetting ...

Страница 3: ...veillance from cameras 46 9 4 Intercom 47 9 5 Releasing switch actuators 48 9 6 Call guard unit 49 9 7 SOS 50 9 8 History 51 10 Cyber security 53 10 1 Disclaimer 53 10 3 Deployment guideline 55 10 4 Upgrading 55 10 5 Backup Restore 55 10 6 Malware prevention solution 55 10 7 Password rule 55 Notice 56 ...

Страница 4: ...ep this manual in a safe place If you pass the device on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power...

Страница 5: ...ntral control panel of the ABB Welcome system and operates exclusively with components from this system The device must only be installed in dry indoor rooms Note Only one WiFi indoor station can be used in the same apartment and this WiFi indoor station must be set to Master mode ...

Страница 6: ...ption before installation The distance between the router and monitors and the construction materials used in the walls are factors that can affect signal quality If the WiFi signal is not strong enough to guarantee correct operation a WiFi repeater must be installed between the router and this device in order to boost the WiFi signal received by this device ...

Страница 7: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Страница 8: ... the door by pressing this button at any time Auto unlock The door is automatically opened after an incoming call Hold this button for more than 3 seconds 5 Mute button In standby mode press this button to mute the ringtone of this indoor station In standby mode long press this button to mute the ringtone of all indoor stations in the same apartment While a call is coming in press this button to r...

Страница 9: ...ndreds digits 3 Master slave function switch Only one indoor station in each apartment can be set as Master ON Master 4 Terminal resistor switch In video installations or mixed audio and video installations the switch must be set as RC on on the last device of the line ON RC on 5 a b bus connector 6 A potential free contact such as a doorbell pushbutton 7 Connector for local power supply Only appl...

Страница 10: ...e range 20 30 V Standby current 24 V 45 mA Operating current 24 V 330 mA Operating temperature 5 C 45 C Single wire clamps 2 x 0 28 mm2 2 x 0 75 mm2 Fine wire clamps 2 x 0 28 mm2 2 x 0 75 mm2 Wireless transmission power Max 20 dBm Wireless transmission standard IEEE 802 11 b g n 2 4 GHz IP level IP 30 ...

Страница 11: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Страница 12: ... interference Do not install the wires of the system bus together with 100 240 V wires Do not use common cables for the connecting wires of the door openers and wires of the system bus Avoid bridges between different cable types Use only two wires for the system bus in a four core or multi core cable When looping never install the incoming and outgoing bus inside the same cable Never install the i...

Страница 13: ...unting Installation Product manual 2TMD042000D0009 13 7 5 Surface mounted installation Surface mounted box Surface mounted installation 79 2 60 60 83 3 83 3 Swiss VDE BS NEMA Italy NEMA Italy 120 7 120 7 ...

Страница 14: ...Mounting Installation Product manual 2TMD042000D0009 14 7 6 Dismantling ...

Страница 15: ...ning 8 1 Registering an account on the MyBuildings portal Access the link https mybuildings abb com and click Register Fill in the form as required to register an account Then activate the user account when you receive the email sent from the MyBuildings portal ...

Страница 16: ...0D0009 16 8 2 Download APP Download the APP from Google Play or the Apple Store via the keyword ABB Welcome Then install the relevant APP on a mobile or tablet Note The following snapshots used in this document were taken on the IOS system ...

Страница 17: ...blet click to open the app select Setup Welcome and then enter the user name password and alias tick the checkboxes to accept all the terms and conditions then click Log in Note If an incorrect password is entered more than 3 times no further attempts are permitted within a certain period of time ...

Страница 18: ... 4 Initial setup 1 Select language In standby status press the setting button to access the language setting screen if it is being powered on for the first time You can tap the program button and key button to select a language maximum of 16 languages ...

Страница 19: ...Commissioning Product manual 2TMD042000D0009 19 2 Accept the license ...

Страница 20: ... registered first Only 2 4G WiFi can be supported by this WiFi indoor station please set the router to 2 4G WiFi before initial setup On the panel press the setting button to access the QR code screen On the APP Home screen tap followed by Pair devices WiFi indoor station to scan QR code on the WiFi indoor station ...

Страница 21: ...Commissioning Product manual 2TMD042000D0009 21 1 APP connect to the panel via WiFi On the APP Configuration screen tap Join to connect APP to the WiFi indoor station ...

Страница 22: ...er home WiFi to the panel Select your home WiFi name and enter the password to transfer your home WiFi to the WiFi indoor station IP address of the WiFi indoor station is set to DHCP by default you can also set a static IP address by unticking the check box DHCP ...

Страница 23: ...enter the MyBuildings account and password and click Log in to MyBuildings After a while APP will pair the WiFi indoor station automatically Note You can use the normal functions in the WiFi indoor station e g receive an incoming call release the lock of the outdoor station etc ...

Страница 24: ...information No Description 1 WiFi name and IP address used by the WiFi indoor station 2 MyBuildings account used by the WiFi indoor station and APP 3 Friendly name used by the WiFi indoor station 4 Friendly name used by APP maximum 8 APPs can be displayed on the screen ...

Страница 25: ...duct manual 2TMD042000D0009 25 8 5 Local settings 8 5 1 Ringtone setting In standby status press the setting button to access the setting screen You can tap the program button to select a ringtone maximum of 5 ringtones ...

Страница 26: ...issioning Product manual 2TMD042000D0009 26 8 5 2 Volume setting In standby status press the setting button to access the setting screen You can tap the program button to select a level maximum of 5 levels ...

Страница 27: ...042000D0009 27 8 5 3 Brightness setting In standby status press the setting button to access the setting screen You can tap the program button to select a level maximum of 5 levels The screen shows the countdown for the last 10 seconds ...

Страница 28: ...MD042000D0009 28 8 5 4 Color setting In standby status press the setting button to access the setting screen You can tap the program button to select a level maximum of 5 levels The screen shows the countdown for the last 10 seconds ...

Страница 29: ...D042000D0009 29 8 5 5 Contrast setting In standby status press the setting button to access the setting screen You can tap the program button to select a level maximum of 5 levels The screen shows the countdown for the last 10 seconds ...

Страница 30: ...g Product manual 2TMD042000D0009 30 8 5 6 Language In standby status press the setting button to access the setting screen You can tap the program button and key button to select a language maximum of 16 languages ...

Страница 31: ...Commissioning Product manual 2TMD042000D0009 31 8 5 7 Information In standby status press the setting button to access the info screen ...

Страница 32: ...Commissioning Product manual 2TMD042000D0009 32 8 5 8 Obtaining product manual In standby status press the setting button to access the info screen Use the APP to scan the QR code on the screen ...

Страница 33: ...duct manual 2TMD042000D0009 33 8 5 9 Restoring to default settings In standby status hold the setting button for 3 s to access the restore screen and follow the steps below to restore the device to the factory defaults ...

Страница 34: ...9 34 8 5 10 Resetting the network configuration In standby status hold the setting button for 3 s to access the restore screen and follow the steps below to reset the network settings Note This operation does not change the MyBuildings settings ...

Страница 35: ...Commissioning Product manual 2TMD042000D0009 35 8 6 Settings via the APP 8 6 1 Entering the APP settings On the APP Home screen follow the steps below ...

Страница 36: ...Commissioning Product manual 2TMD042000D0009 36 The WiFi strength can be viewed on the WiFi indoor station screen when scanning the QR code ...

Страница 37: ...nual 2TMD042000D0009 37 8 6 2 Configuring program buttons On the APP Configuration screen tap Programmable button to set the function for the program button 1 Select a program button 2 Set the function e g Release the 2nd lock ...

Страница 38: ...Commissioning Product manual 2TMD042000D0009 38 8 6 3 Searching cameras On the APP Configuration screen tap Camera list followed by to obtain the camera list ...

Страница 39: ...ct manual 2TMD042000D0009 39 8 6 4 Changing the outdoor station password On the APP Configuration screen tap Outdoor station password enable the Enable password function and enter a password 3 8 digits Tap Finish to save ...

Страница 40: ...o the same MyBuildings account A maximum of 8 APPs can be supported by one WiFi indoor station 1 Pair the APPs The first APP will pair the WiFi indoor station automatically after initial setup The other APPs will no longer require initial setup On the APP WiFi indoor station screen tap the designated WiFi indoor station on the Unpaired area followed by OK ...

Страница 41: ...Commissioning Product manual 2TMD042000D0009 41 2 Unpair the APPs On the APP Configuration screen you can unpair other APPs by tapping Unpair ...

Страница 42: ... WiFi indoor stations APP will pair the WiFi indoor station automatically after the initial setup If you want to manage several WiFi indoor stations you only need to repeat the initial setup 2 Unpair the WiFi indoor stations On the APP WiFi indoor station screen tap the designated WiFi indoor station in the Paired section followed by OK ...

Страница 43: ...default lock on the calling outdoor station 4 Click this icon to end the call 5 Click this icon to release the secondary lock on the calling outdoor station or turn on the light depending on the setting of the paired indoor station s program button 6 Click to add the device to favorites please see the Monitoring chapter for more details 7 Long press the image to take a snapshot ...

Страница 44: ...ing and communication 3 Click this icon to release the default lock on the monitored outdoor station during monitoring 4 Click this icon to release the secondary lock on the outdoor station or release the switch actuator during monitoring depending on the setting of the paired panel s program button 5 Click this icon to initiate a communication with the outdoor station mute by default 6 Click to a...

Страница 45: ...Operation Product manual 2TMD042000D0009 45 Favorites screen On the APP Home screen tap to view the favorite devices Internal network External network ...

Страница 46: ...function is used Please see the Searching cameras chapter for more details On the APP Home screen tap to access the device list screen then tap a designated camera to initiate surveillance No Function 1 Caller ID 2 Click this icon to end the surveillance 3 Not available 4 Click to add the device to favorites 5 Long press the image to take a snapshot ...

Страница 47: ...to set the function of program button to Intercom call before this function is used Please see the Configuring program buttons chapter for more details On the APP Home screen tap to access the device list screen then tap a designated indoor station to initiate a call ...

Страница 48: ...eed to set the function of program button to Switch actuator before this function is used Please see the Configuring program buttons chapter for more details On the APP Home screen tap to access the Access control screen then tap a designated switch actuator and click OK to open it ...

Страница 49: ...Operation Product manual 2TMD042000D0009 49 9 6 Call guard unit On the APP Home screen tap followed by Call guard unit select the indoor station associated with the guard unit to call the guard unit ...

Страница 50: ...Operation Product manual 2TMD042000D0009 50 9 7 SOS On the APP Home screen tap followed by SOS to send an SOS to the guard unit ...

Страница 51: ...e APP Home screen tap followed by Events to access the history records You can tap a designated record to view details Icon Function Incoming call Initiate surveillance Missed call red word in the meantime Long press the image to save the image to the photo album ...

Страница 52: ...Operation Product manual 2TMD042000D0009 52 On an IOS device swipe the record to the left then click to delete the record On an Android device long press the record then click to delete the record ...

Страница 53: ... product the network its system and interfaces against any kind of security breaches unauthorized access interference intrusion leakage and or theft of data or information ABB Ltd and its affiliates are not liable for damages and or losses related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although ABB provides functionality tes...

Страница 54: ...rol and teardown sessions between two or more systems 5060 udp SIP Port 5060 udp is used by SIP Server Flexisip 0 5 0 sofia sip nta 2 0 5061 tcp SIP TLS Port 5061 tcp is used by SIP Server Flexisip 0 5 0 sofia sip nta 2 0 with SSL ciphers that offer communication sessions encryption 5062 udp SIP Local SIP service used by SIP Server Flexisip 0 5 0 sofia sip nta 2 0 50602 udp SIP Used by SIP STUN se...

Страница 55: ...possibly even prevent some of the DoS attacks It is also necessary that switches and routers are properly configured and allow for rate limiting as well as restrict the percentage of CPU power that is allowed to be spent on different interfaces by using rate limiters 10 4 Upgrading Device supports firmware updating by uploading firmware from Welcome App In this mode a signature file will be used t...

Страница 56: ...d specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Страница 57: ... No 7 Fangshan South Road Hi tech area Torch park Xiang An District Xiamen China Tel 86 592 295 9000 Fax 86 592 562 5072 www abb com Copyright 2020 ABB All rights reserved Specifications subject to change without notice 2TMD042000D0009 ...

Отзывы: