Setup and function
Product manual 2CKA001473B9425
│14
Icon of the user
interface
Information
Name: Sensor (rocker)
Control element for the control of free@home functions
Name: Movement detector
Sensor for movement- and brightness-dependent control of free@home
functions
Name: Window contact
Signals "Window open" (Application: automatic deactivation of heating when the
window is open)
Name: Frost alarm
Triggers a frost alarm (Application: Automatic retraction of the blinds, roller
blinds or awnings)
Name: Rain alarm
For the detection of a rain alarm (Application: Automatic retraction of the blinds,
roller blinds or awnings)
Name: Wind alarm
For the detection of a wind alarm (Application: Automatic retraction of the blinds,
roller blinds or awnings)
Name: Switchover heating/cooling
Is used for the switchover of heating/cooling in two-pipe heating/cooling systems
Table 4: Universal detector functions (via connection of external sensor)
Note
Special features of battery-operated detectors:
– It is not possible to assign it the function as blind sensor.
– Light switching can be carried out, for example, via the "Control element"
(rocker) function. However, for this a direct connection with the switch
actuator must be available.
– Only "On/Off" can be activated for the dimming function.
– No change is possible between contact types "Normally closed contact" and
"Normally open contact".
– Only the following statuses are signalled:
■
Universal detector: open, closed