background image

9

Securing Collar

Shroud

0

4

6

4

l

a

n

i

m

r

e

T

.

o

N

e

ri

W

r

o

s

n

e

S

1

)

d

e

R

(

e

v

+

2
3

)

e

u

l

B

(

e

v

4

n

e

e

r

c

S

e

r

u

t

a

r

e

p

m

e

R

r

o

t

a

s

n

e

p

m

o

C

5

k

c

a

l

B

6

n

e

e

r

G

7

w

o

ll

e

Y

5

4

6

4

B

B

T

l

a

n

i

m

r

e

T

.

o

N

e

ri

W

e

r

u

t

a

r

e

p

m

e

T

r

o

t

a

s

n

e

p

m

o

C

6

w

o

ll

e

Y

7

n

e

e

r

G

8

k

c

a

l

B

r

o

s

n

e

S

0

1

)

e

u

l

B

(

e

v

1

1

2

1

)

d

e

R

(

e

v

+

h

t

r

a

e

e

h

t

o

t

n

e

e

r

c

s

e

h

t

t

c

e

n

n

o

C

.

e

s

a

c

e

h

t

n

o

d

u

t

s

Caution. Cable should be of circular cross-section and 

of sufficient diameter to effect a seal inside the cable 

glands.

4.1  Connection to the Dissolved Oxygen Transmitter

Note.  With  floating  ball  and  dip  systems  sufficient 

spare cable should be provided for manipulating the 

floating ball system if space is restricted when installing 

the interconnection cable between the floating ball and 

the transmitter.

Connect the cable (supplied permanently attached to the 

system) to the transmitter unit as detailed in the associated 

transmitter operating instructions, using the terminal 

sleeve colors to correspond with those in the operating 

instructions. For convenience, Tables 4.1 and 4.2 detail the 

connections to transmitters 4640 and 4645 respectively.

4.2  Calibrating the Sensor – Fig. 4.1

The procedures for zero and span calibration are fully described 

in the 4600 Series Transmitter Unit Operating Instructions, to 

which reference should be made.

Note. It is advisable to switch off the water wash before 

starting the calibration procedure. This can be done 

either by turning off at the 4600 transmitter unit, or by 

disconnecting the quick-fit connector.

1)  Remove the system from its mounting bracket.

2)  If the system is a floating ball type, unscrew the securing 

collar and remove the ball – Fig. 4.1.

3)  Carefully wash the exposed sensor capsule with clean 

water.

4)  If the system is a floating ball type, fit the shroud, provided 

with the system, to protect the sensor capsule – Fig. 4.1.

5) Calibrate as instructed in the 4600 Series Operating 

Instructions.

6)  If the system is a floating ball type, remove the protective 

shroud after calibration and replace the ball – Fig. 4.1.

7)  Re-enable the water wash if applicable.

Regular maintenance is limited to periodic cleaning and 

calibration.

The sensor capsule is replaced whenever the existing one 

becomes exhausted – see Section 5.1 Replacing the Oxygen 

Sensor Capsule. Typical sensor life is approximately 12 

months.

Table 4.1 Connections to the 4640 Dissolved Oxygen 

Transmitter

Table 4.2 Connections to the 4645 Dissolved Oxygen 

Transmitter

Fig. 4.1 Floating Ball Shroud for Calibration

4  ELECTRICAL INSTALLATION

Содержание 9408 700

Страница 1: ...xygen system comprises a flat ended sensor mounted into a relatively large diameter spherical flotation collar This form of construction presents to the sample a surface on which it is difficult for rags and other large solids to lodge For more demanding applications on line cleaning is available using the water wash option 9408 series Dissolved oxygen systems ...

Страница 2: ... more information Further publications are available for free download from www abb com analytical or by scanning this code Search for or click on 9408 series Dissolved oxygen systems Data Sheet DS 9408 EN ...

Страница 3: ...npacking 2 2 2 Floating Ball System 2 2 2 1 Assembled Version 2 2 2 2 Kit Version 2 2 3 Dip Systems 3 2 3 1 Assembled Version 3 2 3 2 Kit Version 3 2 4 Submersible System 3 3 MECHANICAL INSTALLATION 4 3 1 Assembling Kit Systems 4 3 1 1 Floating Ball 4 3 1 2 Dip 5 3 2 Installation 6 3 2 1 Floating Ball System 6 3 2 2 Dip Systems 7 3 2 3 Submersible Systems 7 3 3 Water Supply for Water Wash Systems ...

Страница 4: ...I T P O M E T S Y S d r a d n a t S r e t a w h t i W h s a W h s a W h s a W h s a W h s a W c i r t e M 0 5 7 8 0 4 9 2 5 7 8 0 4 9 l a i r e p m I 0 6 7 8 0 4 9 2 6 7 8 0 4 9 s n o i s n e m i D e p i P c i r t e M 0 1 N P t w 3 3 x m m 0 5 d o e p i p S B A l a i r e p m I E s s a l C t w 5 4 x B N 2 1 1 e p i p S B A 2 1 Unpacking After carefully removing the 9408 system from its packing chec...

Страница 5: ...o scale Ø40 mm User supplied tube ABS or PVC 1 9 inches O D Contents 1 Top cap with fixing screw 2 Adaptor 3 Shroud 4 Sensor block with cable attached and dummy sensor fitted 5 Dissovled oxygen sensor capsule 6 Tangit Solvent Cement not provided Contents 1 Top cap with fixing screw 2 Adaptor 3 Shroud 4 Sensor block with cable and water wash tube attached and dummy sensor fitted 5 Dissovled oxygen ...

Страница 6: ...4 4 5 4 3 1 Assembling Kit Systems 3 1 1 Floating Ball Fig 3 1 For installation of the assembled unit see Section 3 2 1 Floating Ball System Fig 3 1 Floating Ball Kit Assembly 3 MECHANICAL INSTALLATION ...

Страница 7: ...5 3 MECHANICAL INSTALLATION 3 1 2 Dip Fig 3 2 For installation of the assembled unit see Section 3 2 2 Dip Systems Fig 3 2 Dip Kit Assembly ...

Страница 8: ...nt cable slack for positioning servicing procedure Make the necessary electrical connections see Section 4 ELECTRICAL INSTALLATION If applicable arrange to have a water wash mains supply available see Section 3 3 and connect to the quick fit connector on the end cap 1 3 2 5 6 4 Standard Swivel Standard Swivel C Standard Swivel C 30 Viewed from above 3 2 Installation Caution The system is supplied ...

Страница 9: ...rovided This is to prevent cable strain and allows the system to be lowered to the required depth 3 2 2 Dip Systems Fig 3 4 Note The standard dip system is supplied with the temperature probe and oxygen sensor body fitted Before fitting the dip tube to any bracket or fixing remove the protective shroud unscrew the dummy capsule from the end of the oxygen sensor body and fit the oxygen sensor capsu...

Страница 10: ...cal water authority and council bylaws Caution The maximum water pressure at the electrode should not exceed 50psi 4 bar At NO time should the sample pressure be allowed to exceed that of the water wash water supply Fit a non return valve if this possibility exists Information As all quick fit connectors used in Water Wash systems incorporate cutoff valves tubes may subsequently be disconnected on...

Страница 11: ...ively 4 2 Calibrating the Sensor Fig 4 1 The procedures for zero and span calibration are fully described in the 4600 Series Transmitter Unit Operating Instructions to which reference should be made Note It is advisable to switch off the water wash before starting the calibration procedure This can be done either by turning off at the 4600 transmitter unit or by disconnecting the quick fit connect...

Страница 12: ... Section 4 2 Calibrating the Sensor Caution Do not leave the new capsule exposed to air for more than 30 minutes as the membrane will dry out Ensure the following steps are done carefully to avoid damaging the membrane covering the silver cathode Align the holes in the end of the ball with the protruding sensor capsule and temperature compensator and replace the ball assembly over the sensor pipe ...

Страница 13: ...n box if applicable and attach a draw wire of suitable length 3 Slacken the cable gland on the end of the boom 4 Remove the self tap screw and pull off the end cap 5 Draw the cable through the gland 6 Unscrew the securing ring of the ball float whilst restraining the ball from turning and withdraw the ball from the elbow union 7 Carefully unscrew the sensor block from the end of the sensor pipe 8 ...

Страница 14: ...ure Compensation Automatic correction by means of integral Pt100 resistance thermometer Accuracy 0 2mgl 1 or 2 saturation within 10 C of the calibration temperature in the range 0 to 35 C Operating Temperature Range 0 to 40 C Operating Pressure Atmospheric Dimensions Floating Ball Ball diameter 203 mm Boom outside diameter Metric 50 mm Imperial 17 8 in 48mm approximately Boom length Assembled 3 me...

Страница 15: ...l System Table 7 1Floating Ball Spares List Fig 7 2Dip System Table 7 2Dip Spares List 7 SPARE PARTS LIST m e t I o N n o i t p i r c s e D o N t r a P 1 y l b m e s s A t a o l F l l a B 5 6 0 8 0 4 9 2 t e k c a r B d r a d n a t S y l b m e s s A c i r t e M 5 1 1 8 0 4 9 l a i r e p m I 6 1 1 8 0 4 9 A 2 t i K y l b m e s s A l e v i w S c i r t e M 5 3 1 8 0 4 9 l a i r e p m I 6 3 1 8 0 4 9 ...

Страница 16: ...rsion Kit Fig A 1 Items in Conversion Kit Fig A 2 Assembled Kit APPENDIX A SUPPORT BRACKET CONVERSION m e t I o N o N o N o N o N n o i t p i r c s e D o N f f O f f O f f O f f O f f O s o N t P 1 s p m a l c m o o B 4 t i K c i r t e M 5 3 1 8 0 4 9 t i K l a i r e p m I 6 3 1 8 0 4 9 2 s d n e s p m a l c m o o B 2 3 s t l o b s p m a l c m o o B 4 4 w e r c s r e d l u o h S 1 5 e t a l p l e ...

Страница 17: ...15 NOTES ...

Страница 18: ...16 NOTES ...

Страница 19: ...Sales Service ...

Страница 20: ...ights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB ABB 2018 ABB Limited Measurement Analytics Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel 44 0 1453 826661 Fax 44 0 1453 829671 Email instrumentation gb abb co...

Отзывы: