After Programming, users can use a telephone to call the Telephone Gateway.

When there is a call-in from Outdoor Station, and telephone is in normal standby:

No.

Function

Command

Example or explanation

1

Accept Call-in

[1] [#]

Commands below can be done via telephone when there is ongoing conversation between Outdoor Station and
telephone:

No.

Function

Command

Example or explanation

1

Switch Light

[5] [#]

To turn on the light switch of the System
Controller or the door actuator

2

Open Door

[3] [#]

Open door during conversation with
Outdoor Station

When there is no ongoing conversation between Outdoor Station and telephone, user calls the Telephone
Gateway, then
1. When Call Divert to Default phone number is active, the telephone will play “Calls are diverted” tone;
2. When Call Divert to Default phone number is not active, the telephone will play “Calls are not diverted” tone.
3. Settings below can be done via telephone:

No.

Function

Command

Example or explanation

1

Call Outdoor Station

[1] [1] [#] to [1] [4] [#] or [1] [#]

1.  11#--14# to call a special Outdoor

Station

2.  1# is also allowed; this will call the

Outdoor Station 1

2

Switch Light

[5] [#]

To turn on the light switch of the System
Controller or the door actuator

[5] [1] [#] to [5] [9] [#]

To be used for the light switch that triggers
a specific light, connected to the flush-
mounted actuator

3

Switch Light when
Indoor Station PIN is
must

[*] Indoor Station Number [*]
Indoor Station PIN [*] [5] [#]

To trigger the light switch of the System
Controller and the door actuator

[*] Indoor Station Number [*]
Indoor Station PIN [*] [5] [1] [#] to [5] [9] [#]

To be used for the light switch that triggers
a specific light, connected to the flush-
mounted actuator

4

Open Specific Door

[3] [1] [#] to [3] [4] [#]

To open special door of the System
Controller and the door actuator

5

Open Special Door
when Indoor Station PIN
is must

[*] Indoor Station Number [*]
Indoor Station PIN [*] [3] [1] [#] to [3] [4] [#]

To open special door of the System
Controller and the door actuator

6

Open the last door-in
Outdoor Station

[3] [0] [#]

7

Open the last door-in
Outdoor Station when
Indoor Station PIN is
must

[*] Indoor Station Number [*]
Indoor Station PIN [*] [3] [0] [#]

8

Call Outdoor Station
when Indoor Station PIN
is must

[*] Indoor Station Number [*]
Indoor Station PIN [*] [1] [1] [#] to [1] [4] [#]
or
[*] Indoor Station Number [*]
Indoor Station PIN [*] [1] [#]

1. 

To call a special Outdoor Station

2. 

1# is also allowed; this will call the
Outdoor Station 1

9

Call the last call-in
Outdoor Station

[1] [0] [#]

10

Call the last call-in
Outdoor Station when
Indoor Station PIN is
must

[*] Indoor Station Number [*]
Indoor Station PIN [*] [1] [0] [#]

11

Activate Default target
phone number

[*] Indoor Station Number [*] [6] [0] [#]

Содержание 83350-500

Страница 1: ...h Ja ege r N eust rukt ur Mo dul St ruktu r Onli ne D oku ment ation Titel bl tt er Di mme r Ti telblat t 659 1 U 1 01 ABB 2 3 m od_ 133 3088 838 540 _15 docx 20 702 5 1 Telephone Gateway 83350 500 8...

Страница 2: ...4 General function 5 4 1 Glossary 5 4 2 Functioning 5 5 Connection 6 5 1 Integration of the Telephone Gateway in your telephone system 6 5 2 Device overview 7 6 Mounting Installation 8 6 1 Requiremen...

Страница 3: ...ectric and electronic devices must not be disposed of with domestic waste The device contains valuable raw materials which can be recycled Therefore dispose of the device at the appropriate collecting...

Страница 4: ...me ntatio n Technis che D aten Dimm er Tec hnisch e Dat en 65 91 U 101 2 3 mo d_1 333 089 085 280 _15 docx 20 703 9 1 General Single wire clamps 2 x 0 6 mm 2 x 1 mm Fine wire clamps 2 x 0 6 mm 2 x 0...

Страница 5: ...rtment the direct accept function has to be deactivated 4 Admin PIN this PIN is used as an administrator password to access the programming mode of the telephone gateway where the Default phone number...

Страница 6: ...appartment have always to be set as slave Please refer to the operating manual of the indoor stations 5 1 Integration of the Telephone Gateway in your telephone system The procedure of integrating the...

Страница 7: ...tallations the terminal resistor must always be deactivated OFF In video installations or mixed audio and video installations the terminal resistor must be activated on the last device of a branch ON...

Страница 8: ...minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect the power 2 Secure against being reconnected 3 En...

Страница 9: ...in PIN No Function Command Example or explanation 1 Enter Admin PIN Admin PIN The default Admin PIN is 1234 3 If the Admin PIN is correct the telephone gateway enters the programming mode and the sett...

Страница 10: ...for programming via IP Gateway and PC 7 4 3 Identifier Identifier Identifier should be an integer from 1 to 99 and has to be unique 14 Reset to Factory Setting 7 3 7 8 Admin PIN Pos 42 B usch J aeg er...

Страница 11: ...oor Station 1 1 to 1 4 or 1 1 11 14 to call a special Outdoor Station 2 1 is also allowed this will call the Outdoor Station 1 2 Switch Light 5 To turn on the light switch of the System Controller or...

Страница 12: ...s must Indoor Station Number Indoor Station PIN 6 1 15 Activate Secondary target phone number Indoor Station Number 6 2 16 Activate Secondary target phone number when Indoor Station PIN is must Indoor...

Страница 13: ...orcall waiting only when direct accept feature is deactivated because further inddorstations in same appartment 4 Call Divert active repeating Call divert to the default number is active Tone is heard...

Страница 14: ...econdary phone number 10 2 Main commands of operation When there is a call in from Outdoor Station and telephone is in normal standby No Function Command Example or explanation 1 Accept Call in 1 When...

Страница 15: ...6 1700 Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of...

Отзывы: