Page 11
© 2023 ABB. All rights reserved.
Edge_I
-
lim_G390_QSG
Version. 2.0
Step 4. Final Assembly
1.
Verify all fuses are fully assembled into each
position of the fuse blocks.
Ground wire
3.
Connect ground wire provided in the G390 kit to
the ground lug located on the bottom of the
base panel assembly. Connect the other end of
the ground wire to the cabinet ground bus.
Torque lug set screw to 45in
-
lb.
Torque screw on ground bus to 65in
-
lb.
Note: 2
-
hole compression lugs are also provided
which can be used instead of the single
-
hole
mechanical lug.
2.
Attach clear, removable panel to the top cover.
Torque to 10in
-
lb.
Figure 13 Fuse blocks
Figure 15 Cabinet grounding
Figure 14 Clear removable panel
QUICK START GUIDE