![ABB Robotics RobotWare 6 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/abb-robotics/robotware-6/robotware-6_applications-manual_450840045.webp)
4 The servo gun opens and closes to test the acceleration. A suggested
acceleration limit is presented.
Tap
Yes
to set this value as acceleration limit.
xx1700002085
Check delta position (final value)
Now that force, speed and acceleration are calibrated, the servo gun's zero
position has probably changed. Perform a new delta position check. See
Check delta position (initial value) on page 33
.
Continues on next page
Application manual - Servo Gun Setup
45
3HAC065014-001 Revision: E
© Copyright 2021 ABB. All rights reserved.
3 Servo Gun Setup wizard
3.2 Running the Servo Gun Setup wizard
Continued
Содержание RobotWare 6
Страница 1: ...ROBOTICS Application manual Servo Gun Setup ...
Страница 2: ...Trace back information Workspace 21A version a10 Checked in 2021 03 16 Skribenta version 5 4 005 ...
Страница 6: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 66: ...This page is intentionally left blank ...
Страница 78: ...This page is intentionally left blank ...
Страница 80: ......
Страница 81: ......