MAINTENANCE
When the “ ” light flashes on the control panel it means that the unit needs to be cleaned
and disinfected.
The user can also clean and disinfect it in advance.
The purpose of such cleaning is to remove residual buildup from the water, reservoir, and pipes.
Automatic cleaning and disinfection with 3 cleaning filters that this unit incorporates
Press and hold the “Get water ” button for 3 seconds to drain the water from inside the unit,
once this process is finished, turn off the unit. Replace the 3 osmosis filters with the three self-
cleaning filters built into this unit.
Uninstall and install by filter numbers and letters (these numbers and letters appear on the
labels of the osmosis and cleaning filters themselves).
Steps to take
How to replace the filters
•
Before starting the filter replacement action, make
sure that the
RO
M10H20
CAT
unit is turned off and
all the water has been drained through the water
drain to drain.
•
Replace the filter as shown in the photo, gently turn
the filter to the left while holding the clamping head
and when you have unscrewed it slide it down.
•
Fit the new filter by sliding upwards and gently turn
it to the right while holding the clamping head.
Whenever you change filters or move the
unit, make sure the switch is in the off
position “ ”.
Maintenance of osmosis filters
The maintenance intervals will depend on the quantity and quality of the water supply
(pay attention to the water filtering capacity of each of the filters) and the environmental
conditions. Cleaning and disinfection of the unit and the replacement of the osmotization
filters by qualified personnel with an interval of 6 to 12 months is recommended, regardless
of the water consumption carried out. However, this period varies depending on the ignition
cycles and the number of times water is dispensed, since if the 120 liters of dispensed water are
exceeded, immediate replacement of the osmotization filters is recommended, even if it has not
been exceeded. even the recommended 6 months.