Chapter 6
Programming
6-22
Parameter 213 – Digital to Analog #2 Gain (D/A 2 Gain)
This parameter scales the D/A #2 Command Value (parameter 59) before it
is output to D/A Converter 2.
To change scaling: Desired Voltage /Rated Current x 0.05553.
Parameter Type:
View/modify in Maintenance level
Minimum Value:
gain of –14.6
Maximum Value:
gain of +14.6
Default Value:
gain of +0.167
Parameter 222 – Id RPM Start *
This parameter is associated with the field weakening function.
Parameter Type:
View/modify in Maintenance level
Minimum Value:
0 rpm
Maximum Value:
6000 rpm
Default Value:
Set by “Setup drive with motor data” routine
Parameter 223 – Id RPM End *
This parameter is associated with the field weakening function.
Parameter Type:
View/modify in Maintenance level
Minimum Value:
0 rpm
Maximum Value:
8000 rpm
Default Value:
Set by “Setup drive with motor data” routine
Parameter 224 – Id Percent Limit (Id Percnt Lim) *
This parameter is associated with the field weakening function.
Parameter Type:
View/modify in Maintenance level
Minimum Value:
0 rpm
Maximum Value:
100%
Default Value:
70%
Parameter 233 – Cable Compensation (Cable Comp)
This parameter is set based on the distance between the motor and drive. It
optimizes drive for resolver cable length variations based on installation.
Parameter Type:
View/modify in Modify level and Maintenance level
Minimum Value:
5 feet
Maximum Value:
600 feet (183 m)
Default Value:
50 feet (15.2 m)
Parameter 234 – Transport Compensation (Transport Comp) *
This parameter specifies the amount of linear transport lag compensation
due to the sample time of the control loops.
Parameter Type:
View/modify in Maintenance level
Minimum Value:
–200
Maximum Value:
+200
Default Value:
81
Содержание ALLEN-BRADLEY 1391-DES
Страница 1: ...User Manual 1391 DES Digital AC Servo Drive...
Страница 9: ...Chapter 1 Introduction 1 10 End of Chapter...
Страница 37: ...Chapter 5 Inputs Outputs and Switch Settings 5 8 End of Chapter...
Страница 84: ...Chapter 8 Start Up 8 16 End of Chapter...
Страница 88: ...Chapter 9 1326 AC Servomotors 9 4 End of Chapter...
Страница 106: ...Chapter 11 Troubleshooting 11 12 End of Chapter...
Страница 122: ...Appendix B Interconnect Drawings B 12 End of Appendix...
Страница 126: ...Appendix C Cable Information C 4 End of Appendix...
Страница 134: ...Appendix E Parameter Record E 8 End of Appendix...
Страница 135: ...Notes...
Страница 136: ...Notes...
Страница 137: ...Notes...
Страница 138: ...Notes...
Страница 139: ...Notes...
Страница 140: ...Notes...
Страница 141: ...Notes...
Страница 142: ...Notes...
Страница 143: ...Notes...
Страница 144: ...Notes...
Страница 147: ...IMC is a trademark of Allen Bradley Company Inc...