Please use the spare jumpers that were kept on JP2 

and JP3. They were kept there to prevent from loosing.

 

 
 
Terminator Settings (JP4 for S1, JP6 for S2, JP8 for S3, JP10 for S4, 

JP5 for S5, JP7 for S6, JP9 for S7, JP11 for S8): 

Jumper Name 

Jumper Settings 

Termination Resistor Setting 

S1 TERM 

(S2 TERM) 
(S3 TERM) 
(S4 TERM) 
(S5 TERM) 
(S6 TERM) 
(S7 TERM) 
(S8 TERM) 

IN 

TXD (DATA- and DATA+) 
Termination Resistor Enabled 

OUT 

(Default) 

TXD (DATA- and DATA+) 
Termination Resistor Disabled 

Note:    IN :   

Jumper Installed 

 

  OUT :    Jumper Not Installed 

 

3.

 

S1~S4 Connector Pin Assignments 

The RS422/485 signals are connected by a DB62 octopus 

cable to 8 DB9-male connectors, the DB9-male pin 

assignment as follows:   

 

 

 

 

 

 

 

 

RS485 TXD Termination Resistor 

Enable/Disable 

1            5 

6           9 

9 Pins   Signal 

  1       TXD- (DATA-)(A) 
  2       TXD+  (DATA+)(B) 
  3       RXD+ 
  4       RXD- 
  5       GND 
  6       - 
  7       - 
  8       - 
  9       - 

Содержание MSC-108B

Страница 1: ...85 over one single PCI slot 16C950 UART built in 128 byte on chip FIFO Up to 921 6 Kbps baud rate over 700 Kbps data throughput Precise RS485 ATTATM Auto Transceiver Turn Around feature to disable the line driver by hardware Optional 15KV ESD surge protection model is available Supports Windows 98SE 2000 and XP 2003 Vista MSC 108B Installation Guide 1 Introduction 2 Connector and Jumper Layout Ter...

Страница 2: ...Please do NOT change it ECHO NO ECHO ECHO Transmitting data will be echoed back NO ECHO Default No echo data S1H S1L S1L Default Reserved for Future Use Please do NOT change it 422 485 485 Default 2 wire RS485 mode 422 4 wire RS422 mode Please note that if the mode were set at 422 mode the ECHO settings will take no effect The Echo mode is useful for the application program to detect if the RS485 ...

Страница 3: ...tting S1 TERM S2 TERM S3 TERM S4 TERM S5 TERM S6 TERM S7 TERM S8 TERM IN TXD DATA and DATA Termination Resistor Enabled OUT Default TXD DATA and DATA Termination Resistor Disabled Note IN Jumper Installed OUT Jumper Not Installed 3 S1 S4 Connector Pin Assignments The RS422 485 signals are connected by a DB62 octopus cable to 8 DB9 male connectors the DB9 male pin assignment as follows RS485 TXD Te...

Страница 4: ...nd the unzipped folder is V6515_RS422_485 Please do NOT use the drivers in its parent directory E IO OXFORD since they are used for RS232 instead of RS422 485 2 PLEASE DO NOT LET WINDOWS AUTO SEARCH THE DRIVERS AMONG THE FOLDERS it will cause problems because the INF files will be conflict in this case Instead please browse to the correct location folder manually to make sure the correct drivers a...

Отзывы: