![AAxeon LNX-1002NM-67-T Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/aaxeon/lnx-1002nm-67-t/lnx-1002nm-67-t_user-manual_450567066.webp)
61
Port Control
In Port Control you can configure the parameters of the connection for each port.
Port:
Scroll up/down the scroll bar and click on the port number to choose a
particular port to be configured.
State:
Enable/disable the port. If the port state is set on ‘Disable’, the port will not be
able to receive or transmit any packet.
Negotiation:
Options include Auto and Force. With this parameter set on
Auto
, the
speed and duplex fields display in grey, which means the port are negotiated
automatically. When you set it on
Force
, you have to set the speed and duplex mode
manually by clicking the pull-down menus of the Speed and Duplex fields.
Speed:
It is available for selecting when the Negotiation field is set on Force. When
the Negotiation field is set on Auto, this field becomes a read-only field displaying in
grey.
Duplex:
It is available for selecting when the Negotiation field is set on Force. When
the Negotiation field is set on Auto, this field becomes a read-only field displaying in
grey.
Flow Control:
Whether the receiving node sends feedback to the sending node is
determined by this item. With this item enabled, if the input data rate of the receiving
device exceeds, the receiving device will send a PAUSE frame which halts the
transmission of the sender for a specified period of time. With this item disabled, the
receiving device will drop the packets it is unable to process.
Security:
When the Security selection is set as ‘
On
’, any access from the device
which connects to this port will be blocked unless the MAC address of the device is
included in the static MAC address table. Keep in mind that the Security item is set
as
On
so that the MAC violation event log/email alert will then be issued. Further
information please see the segments of
MAC Address Table—Static MAC
Addresses
and
System Event Log—Event Configuration
.
Click Apply to have the configuration take effect.
Содержание LNX-1002NM-67-T
Страница 1: ...8 port 10 100TX 2 port 100FX IP 67 Managed Industrial Ethernet Switch User Manual ...
Страница 34: ...29 12 When finished a telnet session is successfully made using the SSH protocol Console via SSH ...
Страница 50: ...45 Syslog Configuration interface ...
Страница 52: ...47 SMTP Configuration interface ...
Страница 59: ...54 SNTP Configuration interface ...
Страница 61: ...56 IP Security interface ...
Страница 65: ...60 Port Statistics interface ...
Страница 67: ...62 Port Control interface ...
Страница 90: ...85 RSTP Port Configuration interface ...
Страница 92: ...87 SNMP System Configuration interface ...
Страница 105: ...100 802 1x System Configuration interface ...
Страница 109: ...104 Static MAC Addresses interface ...