Detail features 

 

 

2 000 users with card and PIN 

 

3 identification modes: card, PIN, card + PIN 

 

Read both 125KHz EM & HID card 

 

PIN length: 4-8 digits 

 

Pulse mode, Toggle mode of lock relay 

 

Wiegand 26-37 input & output 

 

Can be worked as controller or reader 

 

One relay output for door opening, inputs for door status detecting and open door by button 

 

Card block enrollment 

 

Manager cards for adding or deleting card user easily 

 

Very low power consumption (35mA) 

 

Backlight keypad 

 

Light and sound of keypad can be set on/off 

 

Support door bell connection 

 

Built in light dependent resistor (LDR) for anti tamper 

 

Built in buzzer 

 

Red, yellow and green LED display the working status 

 

12-24V DC  

 

Operating Voltage 

12~24V DC 

User Capacity 

2 000  with card and PIN (1234 - default PIN) 

Keypad 

12 keys, 3 x 4 digits and 2 x 6 digits (KZ-900) 

Card Type 

EM & HID 125 KHz card, Mifare (13,56 MHz) 

Card Reading Distance 

3~6 cm (125 kHz), 2~5 cm (13,56 MHz),  

Recommended supply power  2A (controller unit plus electric lock) 
Idle Current 

≤35mA

 

Lock Output Load 

Maximum 1A 

Alarm Output Load 

Maximum 1A 

Bell Output Load 

Maximum 1A 

Operating Temperature 

-20~60

 

Operating Humidity 

0%~95% (non condensing) 

Environment 

Confirms to IP65 

Adjustable Door Relay time 

1~99 seconds, 3s - factory default 

Adjustable Alarm Time 

0~3 minutes, 1 min. - factory default 

Wiegand Interface 

Wiegand 26~37 input & output 

Wiring Connections 

Electric lock, External alarm, Door status (NC),      
Exit button (NO), Bell 

Dimensions: 

KZC-800-U/H/M 
KZC-900-U/H 

 
125 x 83 x 22 mm (HxWxD) 

159 x 43 x 22 mm (HxWxD) 

Technical specifications  

Содержание KZC-800-U

Страница 1: ...Installation Manual INTEGRATED ACCESS CONTROLERS PROXIMITY CARD READERS KZC 800 U H KZC 800 M KZC 900 U H VERSION 1 2 Update 29 12 2014...

Страница 2: ...s 1 door supports up to 2000 users in total each user have one card and one PIN PIN 1234 as de fault should be change for normal using The access control unit supports 1 master code one manager add ca...

Страница 3: ...nd green LED display the working status 12 24V DC Operating Voltage 12 24V DC User Capacity 2 000 with card and PIN 1234 default PIN Keypad 12 keys 3 x 4 digits and 2 x 6 digits KZ 900 Card Type EM HI...

Страница 4: ...ce where controller should be locate Drill 4 holes diameter 6mm rubber bungs on the wall for the screws and 1 hole 30 or 22mm for the cable as written on the sticker figure 1 Fix the metal product bra...

Страница 5: ...de is describe on next pages Wiring diagram Color Function Description Light green BELL_A Bell control output Pink BELL_B Bell control output Red 12V Supply power input 12 24V DC Black GND Supply powe...

Страница 6: ...Unlock when power on such as Electronic Controlling Lock smart lock etc Type B electronic lock Fail Safe lock Unlock when power off such as Electromagnetic Lock Electronic Bolt Lock etc 1N4004 Diode...

Страница 7: ...nly and set 2 10 for opening the door by multi cards 4 5 Toggle Mode In normal mode every time a valid card tag read or PIN input the relay will op erate for the pre set relay pulse time In Toggle mod...

Страница 8: ...unit s buzzer and the external alarm will operate 5 3 Anti duress alarm When read duress card input 8 digits duress PIN the corresponding lock will open at the same time the external alarm will opera...

Страница 9: ...to normal mode if there is no right Master PIN input in 5 seconds After input of right master PIN it will also return to normal mode if there is no valid operation in 30 seconds Press to confirm the i...

Страница 10: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 10 9 1 Basic Operation 5 s 50 ms...

Страница 11: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 11 In 10 minutes if there s 10 times invalid card or wrong password the device will lock on for 10 minutes...

Страница 12: ...r the close in close state the first press key is just to start the keyboard light no any function 10 times consecutive errors including enter an invalid master code user password or anti duress or in...

Страница 13: ...evel is low the Buzzer will beep after 30 seconds or BZ level rising the Buzzer will back to normal When the access controller worked as reader both card number and keypad transmits in Wiegand format...

Страница 14: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 14...

Страница 15: ...7 10000111 8 01111000 9 01101001 01011010 0 11110000 01001011 11 2 Standalone for Single door In this mode the access host uses can open the door by valid card or PIN it supports connecting external c...

Страница 16: ......

Отзывы: