Integrated Access Controller – Installation manual
All rights reserved. © AAT HOLDING S.A.
12
Remark:
①
Every time a valid card/tag read or PIN input in in Toggle mode, the relay
changes state, which will not turn back until read card/tag or input PIN again.
②
The door will open only when read the valid card quantity up to the quantity
set. It is only for Card Only mode.
③
The card number must be consecutive, Card quantity is between 1-2000.
④
After unlocking, enter the normal working state.
⑤
After closed the alarm, anti tamper, anti-duress and door magnetic alarm are
invalid.
⑥
Refers to static state, normal indication according to operation.
⑦
Enter the administrator password correctly, the buzzer alarm in the normal
phonation.
⑧
Each key press or read card, keypad backlight will light 30 sec. delay after the
close, in close state , the first press key is just to start the keyboard light,
no any function.
⑨
10 times consecutive errors including: enter an invalid master code, user
password, or anti-duress or invalid card.
10.
Set Wiegand ouput format option (7-2->26 to 37 bits) concern EM (Unique)
card. HID Prox output format depends of number of bits programing on card.
10. Various Working Modes Application
The device has 3 working modes:
1. Wiegand Reader
2. Standalone for single door (Factory default setting)
3. Anti-pass back for single door
Through Wiegand data lines , can make the device and external card reader are
connected together, to realize of various functions.
Card number and PIN etc information will store in the device.
The external reader only read card or as a device for input PIN, you can connect
with a numbers of readers , but function all same.
Standalone for single door Anti-pass back for single door
Access
Host
(Outside Door)
Access
Host
(Outside Door)
External
Reader
(Inside Door)