Integrated Access Controller – Installation manual
All rights reserved. © AAT HOLDING S.A.
15
Keypad transmission can be set in the following 3 models:
Model 0
The Reader will transmit the PIN data in card number format when it receives
the last key (#) press after PIN code
Format: Decimal card number with 10-digit , Facility Code(1st ~ 4th digit)+ PIN
Code (5th ~ 10th digit)
(Facility code is any digits between 0~15, PIN code is 4~6 digits)
Example: Facility code:15
PIN code: 2999 -> Press 2999#, then output format will be: 0015002999
PIN code: 999999 -> Press 999999#, then output format will be: 0015999999
Model 1: 4-Bit
The output data is provided in following format after every key is pressed:
1 (0001)
,
2 (0010)
,
3 (0011)
4 (0100)
,
5 (0101)
,
6 (0110)
7 (0111)
,
8 (1000)
,
9 (1001)
* (1010)
,
0 (0000)
,
# (1011)
Model 2: 8-Bit
The output data is transmitted in following format after every key is pressed:
1 (11100001)
,
2 (11010010)
,
3 (11000011)
4 (10110100)
,
5 (10100101)
,
6 (10010110)
7 (10000111)
,
8 (01111000)
,
9 (01101001)
* (01011010)
,
0 (11110000)
,
# (01001011)
11.2 Standalone for Single door
In this mode, the access host uses can open the door by valid card or PIN, it
supports connecting external card reader for exiting door.
11.3 Anti-pass back for Single Door
In this mode, access host install outside is for entering door, external reader
inside for exiting door, they build up a single door anti-pass back system,
access host is the anti-pass back master unit.
Read valid card or input PIN on access host, door will open; read valid card
or input PIN on external reader, door will open.
When input duress PIN/Card, the door will open, at the same time, the ex-
ternal alarm operates
When input duress PIN/Card on external reader, the door will open, at the
same time, the external alarm operates.
Open type forced Card Only, the user PIN is invalid.
he users can only enter door when read valid card on access host, and exit
from the inside external reader. If without the entering record from access
host, the users can not exit from the inside reader, also the users can't en-
ter in twice without the first exit record.