                                                                    AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.

 

                                                             All rights reserved.

 

 

 

8. Controller module installation and connections in housing

 

 

Controller and extension module (option) should be installed in a dedicated buffer power 

supply  housing.  Dedicated  housing  APSAAT4,  designed  for  model  KDH

-

KS3024

-

IP,  is 

recommended.

 

Before installing controller module, 4 metal spacer bars (included) should be installed in 

bottom holes. Since controller modules have different sizes, number of holes are made 

at the bottom of housing. The base point for all models, which can be installed in this 

enclosure, is the hole located in upper left corner of controller module installation space 

(location is shown on previous page). The buffer power supply, mounted in this housing, 

has capacity of 5A. Power supply output is split and individually protected 

-

 for modules 

(0,9 A) and locks (4 A). This capacity allows connecting controller module, 2 or 4 read-

ers and 2 or 4 electric locks (even electromagnetic locks with current consumption 500 

mA). Housing is adapted to internal installation of 7Ah battery. 

 

 

NOTE: If it

s necessary to provide longer operation time for controller, separate supply 

power  with  18Ah  rechargeable  battery  should  be  connected  to  the  battery  cables  de-

rived from APSAAT4. To avoid the reverse charge current please install diode in series 

circuit. The manufacturer strongly discourages direct connection to the power supply in 

APSAAT4 battery with a larger capacity than 7Ah because it requires a larger charging 

current. 

 

 

After installing module in the enclosure with screw kit, following connections should be 

made (shown on previous page):

 

• 

connect supply voltage output (AUX 1 12VDC) with controller terminals

 

• 

additional  terminals  on  controller  module  supply  socket  can  be  connected  to  I/O 

module, according to figure on previous page.

 

• 

connect controller RS485 port, using 3

-

core signal wire, with corresponding port on 

I/O module, according to figure and terminals description on page 8

 

• 

install battery at the bottom of housing and connect dedicated wires (red (+) and 

black (

-

), coming from the left side of power supply module).

 

• 

connect housing tamper switch to free alarm line input (enable monitoring sched-

ule in software 

-

 

Always enabled

)

 

• 

connect  readers,  locks,  buttons  and  door  status  wires  to  terminals  on  controller 

edges

 

• 

connect cable with RJ45 connector to Ethernet socket, located in the upper left cor-

ner of the controller module. Other end of the cable should be connected to Ether-

net network. 

 

• 

connect mains power supply 230 VAC to electrical terminal block in the bottom part 

of housing (through existing fuse), in accordance with colors of wires, coming from 

the terminal block to the power supply

 

 

After  finishing  all  connections,  once  again  check,  if  they  are  all  correct  and  only  after 

this turn on the mains voltage 230 V and check if controller is working properly.

 

After  turning  on  mains  voltage,  observe  LED  indicators  on  power  supply  module,  con-

troller and I/O  module. 12V voltage presence indicators should first  light up on power 

supply module, and then on controller (POWER LED) and I/O module.

 

Next, RUN diode on controller module and I/O module should start blinking. Thereafter, 

LEDs on readers should light up.

 

 

Housing  is  equipped  with  dismantled  door,  which  can  be  disassembled  for  connecting 

wires, after disconnecting grounding wire. Housing can be closed with two screws, fas-

tened on the right . Opening of the enclosure is monitored by tamper switch, which gen-

erates alarm, if it

s not temporarily disabled by administrator, for service purposes.

 

Содержание KaDe KDH-KS3012-IP

Страница 1: ...EADER KDH C130U BLACK KDH C130M BLACK KDH CK130U BLACK KDH CK130M BLACK WERSION 2 0 28 11 2018 Installation Manual PROXIMITY CARD READER KDH C130U BLACK KDH C130M BLACK KDH CK130U BLACK KDH CK130M BLA...

Страница 2: ...idelines for controller installation 5 4 KDH KS3024 IP controller module 6 5 Reader exit button and sensor connection 7 6 Power supply lock Ethernet door sensor and I O module connection 8 7 APSAAT4 p...

Страница 3: ...trollers are also provided with additional RS485 port in order to connect extension module MOD2000INOUT List of the most important controller features and parameters is presented in attached table Sys...

Страница 4: ...CP Extension modules connection RS485 dedicated port Readers cards readers ports 4 ports Wiegand interface card formats 26 34 bit Wiegand self defined card types Compatible with reader technology keyp...

Страница 5: ...edicated power supply type APSAAT4 described in further part of manual Wire connections and works with internal controller parts with power on is strictly prohibited as it may damage the device Before...

Страница 6: ...Relay output RL1 Power supply 12 VDC Reader port RDR 1 Reader port RDR 2 Reader port RDR 3 Reader port RDR 4 Exit button door 1 Exit button door 2 Exit button door 3 Exit button door 4 Alarm input 1 A...

Страница 7: ...YELLOW OUT BUZ1 MOD YELLOW OUT BUZ2 MOD GREEN WHITE BROWN BLACK RED GREEN WHITE BROWN READER D3 READER D4 YELLOW OUT BUZ3 MOD YELLOW OUT BUZ4 MOD BUTTON D2 ALARM LINE 1 ALARM LINE 2 ALARM LINE 3 ALAR...

Страница 8: ...ore modules with different addresses to one controller PSU 12VDC Integrated in APSAAT4 Lock NC type lock Lock NO type lock Alarm siren I O module Switch TCP RS485 A RS485 B RS485 GND 1 C 1 NC 1 N0 1 A...

Страница 9: ...uts relay and transistor with LED indication EPS technical output for absence of AC supply PSU output signalling absence of DC voltage power supply failure LoB output signalling low battery voltage Ab...

Страница 10: ...t AUX 1 12VDC with controller terminals additional terminals on controller module supply socket can be connected to I O module according to figure on previous page connect controller RS485 port using...

Страница 11: ...h controller Procedure for creating programming card 1 Push the button Mode located on the upper edge of controller and hold it for 3 seconds Read any card in the reader it will be programming card To...

Страница 12: ......

Отзывы: