4. Click
to reset the MBU 400 and apply the new pincode to the system.
Activating the pincode
The pincode can only be activated or deactivated through the configuration file. See
Protecting Handset Menus
on page
52
for details.
Setting an Access Code
Setting an access code on your gateway ensures only handsets with the same access
code are able to connect to the gateway. The access code can be set through the
handset (see the
Aastra MBU 400 User Guide
for details) or through the Web UI.
Note:
If a handset is trying to register unsuccessfully, it may have the wrong access
code. Change the handset access code to match the gateway access code, and reset
the MBU to initialize handset registration mode.
Note:
A Factory default reset will change the gateway access code to "
0000
" but will
not change the handset access code.
To set the MBU 400 access code using the Web UI do the following.
1. Open the
Pincode Settings
window in the Web UI.
Note: For an administrator, the default Web UI user name is “
admin
” and the
password is “
22222
”.
2. Enter a 4-digit number in the
AC Code
field.
Record your access code number here for reference:
3. Click
to save the new access code.
4. Click
to reset the MBU 400 and apply the new access code to the
system.
5. Change the access code on each handset using
Settings
>
System
Settings
>
Access Code
>
Handset
.
Note:
Changing the AC Code (access code on the Web UI) will not change the access
code on handsets. Handset access codes must be changed individually.
Changing the Web Username and Password
The username and password you use to logon to the MBU 400 Web UI are set to
default values by Aastra Telecom. These can be changed to a username and password
of your choice using the Web UI.
To change the username and password for the MBU 400 Web UI do the following.
1. Open the
Pincode Settings
window in the Web UI.
Note: For an administrator, the default Web UI user name is “
admin
” and the
password is “
22222
”.
2. In the
HTTP Server Username
field, enter a new username.
3. In the
HTTP Server Password
field, enter a new password.
Record your username and password here for reference:
4. Click
to save the new username and password.
Содержание MBU 400