Procedures
3-18
ATP-CNX-040-01 Rel. 1.3, Doc. Rev. 01.07
CNX System Administrator Guide
4
(cont’d)
Global configuration attributes continued
5
Click
to save the configuration to the Aastra CNX and to the CompactFlash card.
Step
Action
Attribute
Default
Valid Values/Description
Permanent Ports
Note:
This attribute must
be set to an appropriate
number of ports before
using Permanent
conferences.
0
0 to 120
Note:
Values are: 0 to 30 for 30-port unit
0 to 60 for 60-port unit
0 to 120 for 120-port unit
Description
: Number of ports reserved for permanent
conferences. This value is subject to ports being physically
configured on the Aastra CNX, either T1/E1 ports and/or
VoIP ports. It is also subject to the licensed number of
ports.
Note:
Permanent ports are not available for scheduled
conferences.
You must provision the T1/E1 ports,
SIP service
, or
H.323
service
on the Aastra CNX before setting the Permanent
Port value. See the following table for applicable settings.
Physical Ports Enabled Maximum Permanent Port Value
1 T1
23
2 T1s
46
4 T1s
92
1 E1
30
2 E1s
60
4 E1s
120
SIP or H.323 service enabled
30
60
120