Interfaces and Terminals as of I7.8
106
Technical Data
sy
d-
023
9/2.
4
– I7.
8
– 0
7
.2009
4
Technical Data
4. 1
Network interfaces
The following technical data applies to the network interfaces:
Basic Access T
•
Standard Euro ISDN interface as per CTR-3
•
Configurable for point-to-point or point-to-multipoint operation
Analogue network interfaces
•
Voice path with A/D and D/A conversion (standard PCM, A-law)
•
Transmission as per ES 201 168 (level country-specific)
•
Signalling as per TBR 21
•
Pulse or DTMF dialling, Flash signal
•
Loop current detection
•
Call charge receive 12 or 16 kHz (frequency and level setting country-specific)
•
CLIP detection in accordance with ETS 300 778-1 (only A150/300)
4. 2
Terminal interfaces
The following technical data applies to the terminal interfaces:
Digital terminal interface AD2
•
Proprietary interface, two-wire
•
2 system terminals per interface
•
Power supply min. 75 mA, limiting at approx. 80 mA,
terminal voltage 36...41 V
•
Line termination in the terminal
•
Transparent transmission of 2 PCM channels