Aastra 470 Скачать руководство пользователя страница 5

Safety information

5

Applications Card CPU2

syd-0421/1.2 – R2.1 – 07.2012

Aastra 400 products contain plastics based on a pure ABS, sheet steel with 
an aluminium-zinc or zinc finish, and epoxy resin-based PCBs. These 
materials are to be disposed of in accordance with the guidelines 
stipulated under current legislation.

Aastra 400 products are disassembled exclusively using detachable screwed 
connections.

Safety information

Reference to hazards

Hazard warnings are affixed whenever there is a risk that improper handling may 
put people at risk or cause damage to the Aastra 400 product. Please take note of 
these warnings and follow them at all times. Please also take note in particular of 
hazard warnings contained in the user information.

Installation and operating instructions

Before you begin with the installation of the Aastra 400 communication server:

• Check that the delivery is complete and undamaged. Notify your supplier 

immediately of any defects; do not install or put into operation any components 
that may be defective.

• Check that you have all the relevant user documents at your disposal.

• During the installation follow the installation instructions for your Aastra 400 

product and observe to the letter the safety warnings they contain. 

Any servicing, expansion or repair work is to be carried out only by technical 
personnel with the appropriate qualifications.

Note:

The integrated Windows operating system on the application card is 
perfectly configured for the integrated applications. Do not for any 
reason whatsoever modify the Windows settings; never install any other 
software or uninstall already installed software or else you will lose any 
right to warranty. 

The application card has its own On/Off pushbutton, although it is connected to 
the same power supply unit as the communication server.  

You can switch on or shut down the communication server and application card 
individually or simultaneously via the integrated user interface. 

Содержание 470

Страница 1: ...Installation Guide Platforms supported Aastra 470 These intructions take you through the installation and initial configuration of the Aastra 470 communication server applications card Innovations wit...

Страница 2: ...a 9 Installing the application card 10 Configuring the application card 13 Configuring the fax server 16 Updating system software 20 Replacing an application card 21 Content Orange Power supply turned...

Страница 3: ...terface for application developers and a multitude of expansion cards and modules The business communication solution with all its elements was designed to cover the full spectrum of communication req...

Страница 4: ...uestion Exclusion of Liability All parts and components of the Aastra 400 communication solution are manufactured in accordance with ISO 9001 quality guidelines The relevant user information has been...

Страница 5: ...ery is complete and undamaged Notify your supplier immediately of any defects do not install or put into operation any components that may be defective Check that you have all the relevant user docume...

Страница 6: ...efects and malfunctions in accordance with Aastra s authorized written functional specification relating to such products during a one 1 year period from the date of original purchase Warranty Period...

Страница 7: ...ht conferred by such a provision or any liability of Aastra in relation to a failure to comply with a guarantee that applies under Division 1 of Part 3 2 of the ACL to a supply of goods or services Th...

Страница 8: ...resupply of the services or ii the payment of the cost of resupply and b in the case of goods i the replacement of the goods or the supply of equivalent goods or ii the repair of the goods or iii the...

Страница 9: ...entele includes acknowledged telephone and data network operators in North America Europe and Africa as well as Internet Service Providers and distributors of renown Aastra Technologies Limited TSX AA...

Страница 10: ...server 6 Check the communication server IP environment with regard to the following Note There should be no other communication server with installed application card on the communication server subne...

Страница 11: ...essing the On Off pushbutton on the card 6 Starting the application card is similar to starting a computer and may take a while The On Off pushbutton LED turns green after the booting process and indi...

Страница 12: ...file 5 Click Apply to upload the licence data and exit the setup wizard Licence data upload might take a while The application card applications are now upgraded and ready for configuration Note The n...

Страница 13: ...erver IP address If the wrong IP address is entered the setup wizard has probably detected othercommunication servers on your subnet Youcansee allthe IP addresses of detected communication servers und...

Страница 14: ...free Click Refresh to refresh the display Note Check whether you have assigned each user the required CTI applications in the communication server user configuration Parameter Explanation Device Name...

Страница 15: ...nformation You can copy backup data to your data storage device with the Download function With the Restore function restore a specific backup from the application card s file system and activate the...

Страница 16: ...ser Use of the fax service is subject to fax licences Fax server settings Parameter Explanation IP address and port display only The fax service IP address is identical to the applications card IP add...

Страница 17: ...ccess prefix and not incanonical format Example Prefix 0 is the default value for most European countries You enter a route prefix The prefix is added to the destination number and the routing takes p...

Страница 18: ...ting 4 Check that the settings for the DDI interpretation are correct Configuration Routing Trunk group view Base number setting and DDI prefix setting 5 Check the user settings to make sure an e mail...

Страница 19: ...communication server via an analogue network interface proceed as follows 1 Follow the above instructions step by step 2 2 Assign the fax server as routing destination for the fax trunk group Configu...

Страница 20: ...e 15 2 Copy the ZIP file with the new version of the system software onto a USB stick and plug the USB stick into one of the USB sockets on the applications card Note Make sure the ZIP file is not loc...

Страница 21: ...ation server and remove the application card 3 Switch on the communication server 4 From your administration PC open your communication server s WebAdmin and log on 5 Navigate up to the card window Co...

Страница 22: ...instructions 5 Installing client applications 15 Installing the application card 10 IP network configuration 14 L Licensing 14 Limited Warranty Australia only 6 Listenansicht 8 O OIP password 15 OIP...

Отзывы: