INSTALLATION

FITTING THE FLUE OUTLET
AND HOT PLATE

The flue outlet spigot is found packed inside the
appliance. The hot plate (blanking plate) is sup-
plied fitted to the top opening and is removed by
turning clockwise (as is the flue outlet).

Smear a very thin layer of fire cement on the faces
of the flue outlet and the blanking plate. Fit the
outlet to the appliance in the desired position .

Lock into place by rotating anti-clockwise and
tighten by tapping with a block of wood and mal-
let from the inside of the appliance. Similarly, fit
the blanking plate to the unused opening. Clean
off any surplus fire cement.

Place appliance on the hearth and make sure that it
is level and does not rock.

Connect the chimney ensuring all joints are sealed
with fire cement.

Fig. 13 Flue and Spigot Fitting

FLUES AND CHIMNEYS

Please remember that chimney draught is
dependent on four main factors:
• Flue gas temperature.
• Flue height.
• Flue size.
• Flue terminal.

The stove must be connected to a suitable and
efficient flue that provides a good updraught to
safely take the products of combustion (fumes)
from the stove outlet to the outside air. To ensure
a good updraught it is important that the flue gases
are kept warm and that the flue size suits the stove.  

The termination of the outlet at the top of the flue
also needs to comply with the Building
Regulations. The minimum effective height of the
flue must be at least 4.5 metres from the top of the
stove to the top of the flue outlet. When warm the
flue draught should be between 0.1 and 0.2 mb.

A chimney may comply with the regulations but
still be subject to down draught and similar
problems. A chimney terminating above the ridge
level is generally less likely to suffer such
problems.

If a new chimney is being provided it should fully
comply with the relevant Building Regulations
that specify the requirements for solid fuel burning
installations. Suitable types of chimney include
the following.

Masonry chimney

built with clay or concrete

liners, or a chimney block system meeting
Building Regulations. These types of chimney
should be installed in accordance with the
Building Regulations and BS 6461: Part 1.

Factory made insulated chimney

complying

with BS 4543: Part 2 (often called "Class 1
prefabricated metal chimney"). These types of
chimney should be installed in accordance with
the Building Regulations and BS 7566: Parts 1 to
4.

*NOTE

THE FLUE PIPE MUST BE FITTED INSIDE THE OUTLET SPIGOT

FAILURE TO DO SO COULD RESULT IN THE SPILLAGE OF

CONDENSATION ECT. RUNNING DOWN THE FLUE.

Содержание Beacon

Страница 1: ...Beacon Multifuel Stoves Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Rev 1 October 2005 AFS 1269 AARROW BEACON 75 SHOWN...

Страница 2: ...which is why we are so confident in the reliability of our product Should you have any questions about our Beacon Stoves that are not covered in this manual please contact the Aarrow dealer in your a...

Страница 3: ...Types 11 Lighting The Fire 11 12 Overnight Burning 12 Over Firing 13 Cleaning 13 Annual Maintenance 14 Accessories 15 INSTALLATION Page General Precautions 16 Handling 16 Hearth 16 Combustible Materi...

Страница 4: ...BE BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www solidfuel co uk THE USE OF SPAR...

Страница 5: ...properly installed and operated a house fire may result installation must comply with the Building Regulations and conform to all relevant fire safety standards Arada Ltd produce a variety of applian...

Страница 6: ...n Multifuel Stoves CHECK LIST Part Description Visual Aid not to scale Beacon 75 Beacon 77 2 Throat plate 1 1 3 Flue spigot 1 5 1 5 4 Hot plate 1 5 1 5 5 Ash pan 1 1 6 Operating tool 1 1 7 Rear liner...

Страница 7: ...75 Beacon 77 Room Heater with Domestic Hot Water with add in boiler type N A N A Max Output to Room kW Max Output to Water kW N A N A Height mm 548 543 Width mm 476 482 Depth mm 345 345 Height to Cent...

Страница 8: ...ating the door knob if hot with a suitable glove anti clockwise to increase the the air inlet clockwise to reduce the air inlet or seal the ash door completely Note Opening or part opening of the ash...

Страница 9: ...DOOR TRIM Beacon fire doors are fitted with a brushed steel finish trim as standard This clips on to the small lugs at the top and bottom of the aperture in the cast iron fire door as a spring fit Wh...

Страница 10: ...oor so that it is at a right angle to the front face of the fire Lift the fire door up off the hinges Gently tap the two hinge pins in a direction to compensate for the misalignment fig 7 Refit the do...

Страница 11: ...nacite Plus Centurion Maxibrite Extracite Pureheat Blazebrite Taybrite Sunbrite Doubles Singles Anthracite Large Nuts and Welsh Dry Steam Coal Large Small Nuts Approval does not cover the use of other...

Страница 12: ...ventilated during this time OVERNIGHT BURNING The appliance will burn overnight provided Sufficient fuel is placed in the firebox The controls are set correctly Excess draught is not present in the c...

Страница 13: ...y clinker forming on the grate should be removed when cold OVER FIRING Do not over fire your appliance Using flammable liquids or too much wood or firing the fire at maximum for prolonged periods may...

Страница 14: ...ged shut down period DOOR GLASS The door glass should remain clear during normal daytimeburning Howeverundercertainconditions such as burning at a low rate with damp wood or overnight burning the glas...

Страница 15: ...n multifuel stove PAINT Matching aerosol paint to tone in any connecting flues pipes or surrounding metalwork INTERCHANGEABLE CANOPIES To fit the interchangeable canopy Fig 8 Remove the front clamps T...

Страница 16: ...EARTH The fire should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth should proje...

Страница 17: ...on the side landings behind the top edge of the grate Fig 11 Fit the throat plate with the single bend and two cut outs to the front facing up The projecting lugs sit on top of the side liners The lo...

Страница 18: ...t it is important that the flue gases are kept warm and that the flue size suits the stove The termination of the outlet at the top of the flue also needs to comply with the Building Regulations The m...

Страница 19: ...rth and fireplace installation Approved Document J of the Building Regulations for England and Wales is available from The Stationery Bookshops and can also be viewed at the ODPM website at www safety...

Страница 20: ...20 Beacon Multifuel Stoves INSTALLATION...

Страница 21: ...THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1 4 PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES A is minimum clearance for non insu...

Страница 22: ...pliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an existing chimney has been refurbished w...

Страница 23: ...Manual AFS1269 AFS1269 AFS1019 AFS1019 AFS1083 AFS1083 AFS010 AFS010 AFS008 AFS008 AFS058 AFS058 AFS009 AFS009 2 Throat Plate 3 Grate 4 Hot Plate 5 Operating Tool 6 Ashpan 7 Flue Spigot Part Descripti...

Страница 24: ...9 AFS088 AFS070 AFS089 AFS047 AFS047 AFS1077 AFS1077 9 Side Liner 10 Back Liner Set 11 Glass Replacement Kit Complete with Gasket 12 Glass Clips and Gasket 13 Hinge kit Comprises 2 Hinges 4 Fixings Pe...

Страница 25: ...AFS1270 AFS1272 AFS094A AFS095 AFS1146 AFS1146 AFS997 AFS997 16 Main Door Assembly Complete with Handle Glass Gaskets Clips and Seal 17 Decorative Door Surround 18 Fire Door Locking Assembly 19 Aarro...

Страница 26: ...ppliance being serviced and checked annually by a quali fied heating engineer The Manufacturers decision shall be final If your appliance proves to be defective as a result of faulty materials or work...

Страница 27: ...Multifuel Stove that is not covered in this manual please contact your Aarrow retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits as th...

Страница 28: ...OPERATING TOOL Model Serial No I ve checked it and it s O K Assembled by Checked by Date of Purchase Name and address of supplier Please ensure installer completes INSTALLATION CHECK LIST details on...

Отзывы: