STEP 6
: (Connecting the hydraulic hoses)
1. Screw the T-fitting with the quick connector on the valve block.
( Fig. 13a )
2. Connect the short hydraulic hose from the T-fitting to the
synchronous valve block.
( Fig. 13b &14 )
3. Put the mobile power-unit cart at the front or rear of the vehicle area.
Fig. 13a
4. Connect the two long hydraulic hoses from the synchronous valve block to the cylinders in the columns.
5. The hose connection is by quick connector. ( Fig. 15)
Fig. 13b
Fig. 14
Fig. 15
STEP 7
: (Install the lifting arms)
Install the swing arms on the carriages using the included 1
1
/
2
” diameter pins. Check for proper
engagement of the arm lock. The rack on the lock should fully engage the gear on the arm. (Fig.
16,17,18)
Fig. 16
Fig. 17
Fig.18
STEP 8
: (Power connection)
Make the Electrical hookup to the power unit (220V Single Phase). It is recommended that a 220 Volt,
30Amp twist lock plug be installed in the power line just ahead of the power unit. Size wire for 30 - amp
circuit.
Warning
:
the wiring must comply with local code. Have a certified electrician make the electrical hook-up
to the power unit. Protect each circuit with time delay fuse or circuit breaker 108V-130V single Phrase 30
Amp.