AAP ESL KIT Скачать руководство пользователя страница 4

Page 4 

DIALLER SETUP - 

FOR MONITORING STATION 

 

Your Elite S-Lite Controller is equipped with an on board dialler, capable of communicating in contact id. 

If you are required to connect to a central monitoring station you will need to complete the following steps.  
Contact a monitoring station of your choice, they will issue you an account number and telephone number.  

 

Name of monitoring station___________________________    Contact phone number_____________ 

Your Account number                 [   ][   ][   ][   ] 
Telephone number  1    [   ][   ][   ][   ][   ][   ][   ][   ][   ][   ][   ] 

Telephone number  2    [   ][   ][   ][   ][   ][   ][   ][   ][   ][   ][   ] (this is optional)  

Step 1: 

Connect across the incoming phone line between the street and the first jack point.  

 
Step 2: 

Enable the dialler. In Installer Mode press 

<PROGRAM> <175> <ENTER> <1> <ENTER> 

 

 

(then turn ON option 1) and 

<ENTER>.

 

 

 

P 175 E 1 E 1 E    

 

 
Step 3: 

Account number. In Installer Mode press 

<PROGRAM> 

 

<62> <ENTER> <1> <ENTER>  

 

 

(then put in the 4 digit account number) 

<ENTER>.  

 

 

i.e.  

P 62 E 1 E 1234 E 

 (the new account code would be 1234) 

 

 

Step 4:  

Phone number 1, In Installer Mode press 

<PROGRAM> <181>

 

<ENTER> <1> <ENTER> 

 

 

(now key in your given phone number 1) and 

<ENTER>.  

 
 

 

I.e.  

P 181 E 1 E 095551234 E 

(the new phone number 1 would be 095551234) 

 

 

 

Phone number 2, In Installer Mode press 

<PROGRAM> <181>

 

<ENTER> <2> <ENTER> 

 

 

(now key in your given phone number 2) and 

<ENTER>.  

 

 

 

I.e.  

P 181 E 2 E 095554321 E 

(the new phone number 2 would be 095554321) 

 

Step 5: 

Prepare for dialler test. First we will temporarily disable sounders. In Installer Mode press  

 

 

<PROGRAM>

 

<25>

 

<ENTER> <9> <ENTER> <1> <2> <ENTER> 

(outputs 1 & 2 have 

 

 

been disabled until an Arm cycle has taken place).  

 

 

 

P 25 E 9 E 1 2 E  

 

 
Step 6: 

Exit program mode by pressing and holding 

<PROGRAM> 

 

 

Step 7: 

Testing. Press the 

<ARM> 

button the exit delay will start. When it stops walk in front of each  

 

 

detector, then go back to the keypad to see if LED’s 1 & 2 are now flashing and the keypad is  

 

 

squealing. As soon as the entry delay has finished, the panel should start dialling out. You wont 

 

 

be able to hear it dial out, but if you pick up a phone in the house it should not have a dial tone. 

 

 

Leave the panel for about 2 minutes then key in a user code 

i.e. <1 2 3> 

followed by 

<ENTER>. 

 

 

The panel should now be disarmed.  

 

Step 8: 

Confirming. Now contact the monitoring station and ask them if they received 3 different monitoring  

 

 

messages from your account code. They should be:       

 

 

Alarm activation on zone 1.     

 

 

Alarm activation on zone 2.     

 

 

Alarm restored.  

 

 

 

 

 

 

Dialler Setup is Complete

 

Содержание ESL KIT

Страница 1: ...QUICKFIT INSTALL HOOK UP SHEET FOR ESL KIT REV 1 17 OP ...

Страница 2: ...ENTER now put in the new reset time 0 9999 and ENTER P 40 E 1 E E output 1 default reset time is 300 seconds P 40 E 2 E E output 2 default reset time is 300 seconds Changing Installer code There is only one installer code this is for you to remember As default it is 000000 You must be in Installer mode to change the code press PROGRAM 25 ENTER 1 ENTER then put in your new code and ENTER P 25 E 1 E...

Страница 3: ...nd check the user code slots to see weather the right codes has been entered 4 Next to press the ARM button to see if there is enough time to get out of the house before the exit delay beeps stop Can you get out before the beeps stop yes if no you will need to extend the exit delay 5 Now with the panel ARMED see if you can get back inside to the keypad and disarm the alarm before the sirens go off...

Страница 4: ...34 E the new phone number 1 would be 095551234 Phone number 2 In Installer Mode press PROGRAM 181 ENTER 2 ENTER now key in your given phone number 2 and ENTER I e P 181 E 2 E 095554321 E the new phone number 2 would be 095554321 Step 5 Prepare for dialler test First we will temporarily disable sounders In Installer Mode press PROGRAM 25 ENTER 9 ENTER 1 2 ENTER outputs 1 2 have been disabled until ...

Страница 5: ...nstaller Mode press PROGRAM 182 ENTER 1 8 ENTER now turn ON option 2 and ENTER i e P 182 E 1 E 2 E phone number 1 is now set to Domestic Dial Step 5 Maximum Dial Attempts Each phone number set to Domestic Dial will need dial attempts changed In Installer Mode press PROGRAM 184 ENTER 1 8 ENTER 3 ENTER i e P 184 E 1 E 3 E phone number 1 now has maximum dial attempts set to 3 Step 6 Reporting Options...

Страница 6: ...ATION Page 6 Screw PCB down in these points BATTERY GOES HERE WIRE 230V MAINS IN HERE INSIDE VEIW OF PLASTIC CABINET POP OUT CABLE CLAMP FOR MAINS LEAD End view of Keypad Carefully slide a flat blade screwdriver into slots to remove back Removing back from keypad CUT THIS SUPPORT OFF ...

Страница 7: ... defect or fault return the goods or defective parts thereof to Arrowhead Alarm Products Freight to and from our stores is your care The company shall not be liable for any direct or consequential loss or damage attributed to the fault Nor shall the company be liable for any personal injury of any kind attributable to the fault The customer will keep the company indemnified against any such claim ...

Страница 8: ... SILICONE FILLED CRIMPS TELEPHONE WIRING OPTION 1 Standard analogue line PIEZO SIREN 2k2 2k2 P N Keypad Terminal Block ON 12 0V C D 1 ANT RX 16 MF349 v090618 303 433 915MHz Optional Radio Receiver Connects here PIR 2 PIR 1 INTERNAL EXTERNAL KEYPAD 1 RECEIVER PHONE LINE OFF THE STREET WITH ADSL ENABLED ADSL MODEM LINE PHONE DSL008 ADSL LINE FILTER SILICONE FILLED CRIMPS TELEPHONE WIRING OPTION 2 wi...