Page 4
DIALLER SETUP -
FOR MONITORING STATION
Your Elite S-Lite Controller is equipped with an on board dialler, capable of communicating in contact id.
If you are required to connect to a central monitoring station you will need to complete the following steps.
Contact a monitoring station of your choice, they will issue you an account number and telephone number.
Name of monitoring station___________________________ Contact phone number_____________
Your Account number [ ][ ][ ][ ]
Telephone number 1 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]
Telephone number 2 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ] (this is optional)
Step 1:
Connect across the incoming phone line between the street and the first jack point.
Step 2:
Enable the dialler. In Installer Mode press
<PROGRAM> <175> <ENTER> <1> <ENTER>
(then turn ON option 1) and
<ENTER>.
P 175 E 1 E 1 E
Step 3:
Account number. In Installer Mode press
<PROGRAM>
<62> <ENTER> <1> <ENTER>
(then put in the 4 digit account number)
<ENTER>.
i.e.
P 62 E 1 E 1234 E
(the new account code would be 1234)
Step 4:
Phone number 1, In Installer Mode press
<PROGRAM> <181>
<ENTER> <1> <ENTER>
(now key in your given phone number 1) and
<ENTER>.
I.e.
P 181 E 1 E 095551234 E
(the new phone number 1 would be 095551234)
Phone number 2, In Installer Mode press
<PROGRAM> <181>
<ENTER> <2> <ENTER>
(now key in your given phone number 2) and
<ENTER>.
I.e.
P 181 E 2 E 095554321 E
(the new phone number 2 would be 095554321)
Step 5:
Prepare for dialler test. First we will temporarily disable sounders. In Installer Mode press
<PROGRAM>
<25>
<ENTER> <9> <ENTER> <1> <2> <ENTER>
(outputs 1 & 2 have
been disabled until an Arm cycle has taken place).
P 25 E 9 E 1 2 E
Step 6:
Exit program mode by pressing and holding
<PROGRAM>
Step 7:
Testing. Press the
<ARM>
button the exit delay will start. When it stops walk in front of each
detector, then go back to the keypad to see if LED’s 1 & 2 are now flashing and the keypad is
squealing. As soon as the entry delay has finished, the panel should start dialling out. You wont
be able to hear it dial out, but if you pick up a phone in the house it should not have a dial tone.
Leave the panel for about 2 minutes then key in a user code
i.e. <1 2 3>
followed by
<ENTER>.
The panel should now be disarmed.
Step 8:
Confirming. Now contact the monitoring station and ask them if they received 3 different monitoring
messages from your account code. They should be:
Alarm activation on zone 1.
Alarm activation on zone 2.
Alarm restored.
Dialler Setup is Complete