When you have finished the programming options, a quick test is required to confirm all hardware and 

software is working correctly. 
Run through the steps below and tick the box if it operates successfully. 

Make sure no one is moving around the house, as this could affect the test. 

 

1

. The keypad should not have any zone lights on. The ready light should be on steady.           

 

Are all the lights right

?

  yes   

if no 

there could be a wiring problem check your work.  

 

2

. Get someone else to walk in front of the sensors, the corresponding zone 1 or 2 should come on.            

 

Do they come on at the right time?   

yes              

if no 

there could be a wiring problem check your work.  

 

3

. Now test all the user codes. Start by typing in user code 1 followed by enter, the keypad should start         

beeping as it arms, then type it in again, the keypad should go quiet as it disarms.  
Repeat this test for all user codes. 

 

Do all of the codes arm and disarm the panel?   

yes            

if no 

go back and check the user code slots, to  

 

 

 

 

 

 

 

 

 

         see weather the right codes has been entered. 

 

4

. Next to press the ARM button, to see if there is enough time to get out of the house, before the exit delay 

beeps stop. 

 

Can you get out before the beeps stop?    

yes          

if no 

you will need to extend the exit delay. 

 

5

. Now with the panel ARMED see if you can get back inside to the keypad and disarm the alarm before the 

sirens go off. 
 

Can you disarm before the sirens go off?  

yes          

if no 

you will need to increase the entry delay times. 

 

6

. The final test is to make sure the 

sirens and strobe 

go off after the entry delay has finished. So arm the 

alarm, wait for the beeps to stop then move in front of a sensor, the keypad should start beeping again and as 

soon as the entry delay is up the sirens and strobe will go off, once checked enter a user code to disarm and 

turn of the sounders. 

 

Does the external siren work?   

yes

          

 

 

Does the external strobe work?    

yes

   

 

Does the internal siren work?

     yes           

if no 

to any of these check wiring and polarity of devices. 

 

 

The alarm panel is now ready for general use  

 

 

Are you happy with the installation?      

 
 

 

yes

 

     

 

 
 

 

 

 

Sign here. 

 

 

 

                    Date.         /       /

 

 
 

  

Page 3 

TESTING   

Содержание ESL KIT

Страница 1: ...QUICKFIT INSTALL HOOK UP SHEET FOR ESL KIT REV 1 17 OP ...

Страница 2: ...ENTER now put in the new reset time 0 9999 and ENTER P 40 E 1 E E output 1 default reset time is 300 seconds P 40 E 2 E E output 2 default reset time is 300 seconds Changing Installer code There is only one installer code this is for you to remember As default it is 000000 You must be in Installer mode to change the code press PROGRAM 25 ENTER 1 ENTER then put in your new code and ENTER P 25 E 1 E...

Страница 3: ...nd check the user code slots to see weather the right codes has been entered 4 Next to press the ARM button to see if there is enough time to get out of the house before the exit delay beeps stop Can you get out before the beeps stop yes if no you will need to extend the exit delay 5 Now with the panel ARMED see if you can get back inside to the keypad and disarm the alarm before the sirens go off...

Страница 4: ...34 E the new phone number 1 would be 095551234 Phone number 2 In Installer Mode press PROGRAM 181 ENTER 2 ENTER now key in your given phone number 2 and ENTER I e P 181 E 2 E 095554321 E the new phone number 2 would be 095554321 Step 5 Prepare for dialler test First we will temporarily disable sounders In Installer Mode press PROGRAM 25 ENTER 9 ENTER 1 2 ENTER outputs 1 2 have been disabled until ...

Страница 5: ...nstaller Mode press PROGRAM 182 ENTER 1 8 ENTER now turn ON option 2 and ENTER i e P 182 E 1 E 2 E phone number 1 is now set to Domestic Dial Step 5 Maximum Dial Attempts Each phone number set to Domestic Dial will need dial attempts changed In Installer Mode press PROGRAM 184 ENTER 1 8 ENTER 3 ENTER i e P 184 E 1 E 3 E phone number 1 now has maximum dial attempts set to 3 Step 6 Reporting Options...

Страница 6: ...ATION Page 6 Screw PCB down in these points BATTERY GOES HERE WIRE 230V MAINS IN HERE INSIDE VEIW OF PLASTIC CABINET POP OUT CABLE CLAMP FOR MAINS LEAD End view of Keypad Carefully slide a flat blade screwdriver into slots to remove back Removing back from keypad CUT THIS SUPPORT OFF ...

Страница 7: ... defect or fault return the goods or defective parts thereof to Arrowhead Alarm Products Freight to and from our stores is your care The company shall not be liable for any direct or consequential loss or damage attributed to the fault Nor shall the company be liable for any personal injury of any kind attributable to the fault The customer will keep the company indemnified against any such claim ...

Страница 8: ... SILICONE FILLED CRIMPS TELEPHONE WIRING OPTION 1 Standard analogue line PIEZO SIREN 2k2 2k2 P N Keypad Terminal Block ON 12 0V C D 1 ANT RX 16 MF349 v090618 303 433 915MHz Optional Radio Receiver Connects here PIR 2 PIR 1 INTERNAL EXTERNAL KEYPAD 1 RECEIVER PHONE LINE OFF THE STREET WITH ADSL ENABLED ADSL MODEM LINE PHONE DSL008 ADSL LINE FILTER SILICONE FILLED CRIMPS TELEPHONE WIRING OPTION 2 wi...