Power supply 
display 

Power supply 
type 

Displays the power currently used. 

Displays the remaining battery charge.   

11 

Current time 
display 

Current time 

Displays the current time. 

5-4 Pause Display 

When the home display is being shown, press the PAUSE key to pause the waveform. 

 

Note

 

  When the display is paused, press the HOME key or PAUSE key to return to the home display. 

  In the Pause display, press the ECG RECORD START/STOP key to print the ECG waveform of 16 

seconds occurred right before the PAUSE key is pressed. 

  In the pause display, after about 5 minutes of inoperation, the home display will be indicated. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание TM-2560G

Страница 1: ...TM 2560G TM 2564G TM 2560GP TM 2564GP VITAL SENSOR GRAPHIC MODEL INSTRUCTION MANUAL WM PD4000753...

Страница 2: ...duced transmitted transcribed or translated into any language in any form by any means without the written permission of A D Company Ltd The contents of this manual and the specifications of the instr...

Страница 3: ...ropean Directive 93 42 EEC for Medical Products This is evidenced by the CE mark of conformity accompanied by the reference number of a designated authority Warning Definitions The warnings described...

Страница 4: ...re used The following points should be considered before use Check to make sure the instrument operates safely and accurately Check all hoses and cables for proper connection and deterioration When th...

Страница 5: ...e patient s or operator s safety Turn the power off and disconnect the power cable from the outlet Affix a notice such as Out of Order and Do Not Use on the device Ask the nearest dealer for services...

Страница 6: ...erator and the patient before use Humidify the room Lightening Lightening occurring nearby may induce great amount of voltage to the instrument Under such a condition operate the instrument as follows...

Страница 7: ...e is 3 5 2 m 1 5 m meters long Using a longer hose may lower the amplitude level of the detected pulse and affect the measurement Do not use a twisted or tangled hose as it is The air may be trapped i...

Страница 8: ...essel When nails are coated with nail polish When physical movement is present When the sensor is firmly tightened When carboxyhemoglobin and or methemoglobin concentration cannot be ignored During el...

Страница 9: ...fectant Flex type Disposable sensor Though the sensor is suitable for long term monitoring check the skin and sensor mount at fixed intervals every 8 hours If a change or discoloration in skin is dete...

Страница 10: ...ed contact the agent you purchased it from Retain the packing materials which are required to transport this instrument Check that the following articles are included when you unpack the instrument TM...

Страница 11: ...ix...

Страница 12: ...Printer Keys 9 3 5 Symbols 9 4 Preparation Before Use 10 4 1 Installation Site 10 4 2 Power Supply 10 4 3 Installation Procedure 13 4 4 Printer Paper Loading Procedure 13 5 Displays 14 5 1 Home Displ...

Страница 13: ...ata 35 6 12 Power Supply 37 6 13 Printing the Measurement Data 37 6 14 Function Setting 40 7 Maintenance 42 7 1 Cleaning 42 7 2 Calibration 43 7 3 Assembling the Cuff 44 7 4 Disposing of the Instrumen...

Страница 14: ...to an optimum pressure according to the patient s blood pressure to prevent excessive pressurization The interval measurement is an exact time measurement synchronized with the built in clock allowin...

Страница 15: ...art rate pulse rate SpO2 and temperature Flashes value and alarm lamp and sounds alarm in an emergency Display Backlit TFT color LCD 5 inches 320 x 234 dots Displaying function Waveform ECG waveform p...

Страница 16: ...ls CON 2 5 3 5 10 15 20 30 60 90 120 min Maximum length of CON measurement is 5 minutes After five minutes the interval is switched to 5 min interval automatically SpO2 Measurement method 2 wavelength...

Страница 17: ...6 3 Part Names 3 1 TM 2560G TM 2564G...

Страница 18: ...7 3 2 TM 2560GP TM 2564GP...

Страница 19: ...AUSE key Pauses the ECG waveform or plethysmograph Returns to the previous home display when pressed again 5 keys Goes to the following display from the home display key Goes to the setting mode displ...

Страница 20: ...witch is ON Indicates that the POWER switch is OFF Indicates that the degree of protection against electrical shock is type BF Applicable to the SpO2 sensor Indicates that the degree of protection aga...

Страница 21: ...er Supply The instrument can be operated using an AC adapter or battery When an AC adapter is used 1 Connect the supplied power cable to the AC adapter Insert the plug on the other end of the power ca...

Страница 22: ...portion that the cables come out to the groove of the battery compartment 6 Slide the cover to install it 7 Screw the cover Caution Use the specified battery only Switching the power supply When the A...

Страница 23: ...week when the AC adapter is kept connected after 15 hour charging Normal condition Flashes every ten seconds Supplementary charging is being performed Occurs in the early stage of 15 hour charging No...

Страница 24: ...e SpO2 extension cable to the SpO2 connector of the instrument and lock it 4 Connect the SpO2 cable to the SpO2 extension cable 5 Connect the ECG extension cable to the ECG connector of the instrument...

Страница 25: ...d pressure 2 traces Default display 6 Sleep mode Emphasizes the blood pressure values Blank display 2 Waveform 2 traces 5 Temperature 1 trace Lengthened waveform display area Emphasizes the heart rate...

Страница 26: ...e the comparison of the item indicated in each display For example Middle of the blood pressure is not the same as Middle of the temperature When the temperature probe ID is set to OFF two home displa...

Страница 27: ...e display Here the basic parameters are described as they appear in the home display Please note that the composition depends on the instrument model TM 2564G standard home display Blood pressure 2 tr...

Страница 28: ...lay Red circle Displays a red circle near DIA when the limit values are set Mean blood pressure Displays the value after measurement Retained until the next measurement 3 Mean blood pressure display M...

Страница 29: ...essure is measured 11 Blood pressure unit display Blood pressure unit Displays mmHg as the unit of blood pressure 12 Error message Blood pressure measurement error Displays the error that occurs durin...

Страница 30: ...detection 21 SpO2 pulse bar graph display SpO2 pulse bar graph Displays the bar graph in synchronization with the SpO2 pulse 22 Blood pressure pulse graph display Blood pressure pulse graph Displays t...

Страница 31: ...d values Displays the memory data in order of storage The greater the number is the newer the data is Displays the number date and the values of memory data 3 Page number display Page number Displays...

Страница 32: ...mber total page to indicate where the displayed data is among the whole data Displays blood pressure data in bar graph in the range of 0 to 200 mmHg 4 Scale display Displays SpO2 data using in the ran...

Страница 33: ...he home display is being shown press the PAUSE key to pause the waveform Note When the display is paused press the HOME key or PAUSE key to return to the home display In the Pause display press the EC...

Страница 34: ...ing sub menu items Displays the list of sub menu items corresponding to the selected menu with one currently selected and its value being highlighted Press the key to select the item to be changed 3 S...

Страница 35: ...e changed frequently Overwritten in the home display 2 Setting items display Setting items Displays the quick setting items corresponding to the menu and sub menu selected in the setting mode display...

Страница 36: ...of the instruction manual when attaching the Cuff ECG electrodes SpO2 sensor Attaching the cuff 1 Hold the cuff with the hose pointing toward the lower part of the arm 2 Wrap the cuff around the uppe...

Страница 37: ...de and patient Wipe the body sites that are wet with the alcohol using a clean dry cotton Do not use the disposable electrode when the paste is dry For ECG monitoring the chest lead configuration as s...

Страница 38: ...Note Do not apply the sensor on the same arm with an arterial catheter inserted or the cuff attached Using the same arm will lower the reliability of the measurement data Attaching the temperature pr...

Страница 39: ...ation 1 In the home display press the MENU key key to indicate the setting mode display 2 The selected menu and sub menu items are highlighted and the value of the selected item appears in the box at...

Страница 40: ...y 10 200 SYS Lower OFF 30 200 by 10 70 Upper OFF 30 200 by 10 150 DIA Lower OFF 10 200 by 10 40 mmHg Upper OFF 50 220 by 10 170 HR PR Lower OFF 30 150 by 10 40 bpm Upper OFF 75 99 by 1 SpO2 Lower OFF...

Страница 41: ...rm Lower ECG SpO2 Sets the waveform displayed at the lower area Year 2000 2099 Month 1 12 Day 1 31 Hour 0 23 Clock Minute 00 59 Sets the clock Alarm sound 1 4 2 Sets the alarm buzzer volume Click soun...

Страница 42: ...operation 1 In the home display press the QUICK SETTING key 2 The quick setting window opens and the selected value is highlighted 3 Press the QUICK SETTING key to open the next menu 4 Press the or k...

Страница 43: ...s not exhausted remove the cuff from the patient immediately Blood pressure measuring procedure 1 Press the NIBP START STOP key to start a measurement 2 When AUTO is selected for pressurization the cu...

Страница 44: ...ome display and starts the continuous measurement after 10 seconds 3 After 5 minutes the continuous measurement switches to the 5 minute interval measurement and the display switches from CYCLE CON to...

Страница 45: ...he instruction manuals of the temperature probe and the temperature receiver unit for details Note The communication status is displayed by the antenna mark 6 9 Measuring the Heart Rate Pulse Rate The...

Страница 46: ...ALARM OFF key If the condition that caused the alarm persists after two minutes the alarm will sound again The ALARM OFF mark illuminates while the alarm is stopped 6 11 Storing Deleting Data Note Th...

Страница 47: ...lay 2 Press the key to indicate the memory deletion display 3 Press the key to cancel the deletion and return to the list display 4 Press the key to perform deletion After deletion the list display ap...

Страница 48: ...ing printing may damage the print head Auto printing When List or Trend is selected for Auto print in the setting mode printing is performed automatically each time blood pressure is measured and at t...

Страница 49: ...is printed at the beginning and end of the waveform data The waveform for calibration indicates that for 1mV The printing speed is fixed to 25mm sec And the printing is performed at the same gain as...

Страница 50: ...39 Trend printing Prints the measurement data in trend form using the symbols below Systolic Diastolic SpO2 x heart rate pulse rate temperature ECG waveform...

Страница 51: ...holding down the QUICK SETTING key turn on the POWER switch to indicate the function setting display The selected item is highlighted 2 Press the or key to select the item 3 Press the or key to change...

Страница 52: ...data hold OFF ON Whether to retain the previous data or not when the POWER switch is turned off ON to retain S22 Averaging pulse 1 4 8 Sets the number of ECG pulse rate data for moving average S23 Ju...

Страница 53: ...ument exterior with a dry soft cloth If the instrument is stained with blood chemical substance or dirt wipe the instrument off using a cloth dampened with a mild detergent For cleaning a patient s bo...

Страница 54: ...played on the manometer The difference should be within 4 mmHg Turn off the POWER switch Checking the exhaustion speed Connect the optional 500 cc cylinder or the equivalent to the instrument as shown...

Страница 55: ...follow the local regulations Cuffs and sensors The cuffs and sensors used by the patient may cause infection Dispose of them as medical waste Built in lithium battery When disposing of the instrument...

Страница 56: ...ected E44 Physical movement is detected E45 The diastolic blood pressure cannot be determined E46 The mean blood pressure cannot be determined E48 The systolic blood pressure cannot be determined E61...

Страница 57: ...502P30 S ECG patient cable AX KO1924 ECG extension cable AX KO1839 SpO2 related Durasensor Finger clip AX SPDS 100A Oxiband Adult Neonate AX SPOXI A N Oxiband Pediatric Infant AX SPOXI P I Oxisensor A...

Страница 58: ...e reaches the highest as the mean blood pressure and the point where the amplitude decreases gradually and becomes small as the diastolic blood pressure Actually the pressure sensor detects the subtle...

Страница 59: ...s The small cuff yields high blood pressure regardless of the proper cuff pressure or normal artery The large cuff yields low blood pressure especially for those who suffer from severe arteriosclerosi...

Страница 60: ...properties of oxygenated hemoglobin and reduced hemoglobin Refer to Figure A 1 A pulse oximeter uses the difference in light absorbing properties of hemoglobin to obtain arterial oxygen saturation Whe...

Страница 61: ...ecreases to a negligible level as they grow When abnormal hemoglobin has increased due to carbon dioxide poisoning or methemoglobinemia a measurement error occurs For those suffering from these condit...

Страница 62: ...51 Appendix B External Dimensions TM 2560G TM 2564G TM 2560GP TM 2564GP Unit mm...

Отзывы: