A&D SK-1000WP Скачать руководство пользователя страница 2

 

- 1 - 

SAFETY PRECAUTIONS 

 

 All safety messages are identified by the following, “

WARNING

” or 

CAUTION

”, of ANSI Z535.4 (American National Standard Institute: 

Product Safety Signs and Labels). The meanings are as follows: 

WARNING

 

A potentially hazardous situation which, if not 
avoided, could result in death or serious injury.

CAUTION

 

A potentially hazardous situation which, if not 
avoided, may result in minor or moderate injury.

 
 

  This manual is subject to change without notice at any time to 

improve the product.   

 

  Product specifications are subject to change without any obligation 

on the part of the manufacturer. 

 

  When using the SK-WP, the following safety precautions should 

always be followed. 

 

WARNING Use only the specified AC adapter for the scale. Other 

adapters may cause damage. (AC adapter is optional.) 

 

 

Internal service or adjustment to this product should be 
performed by a qualified person. 

 

CAUTION

  Avoid installing the scale in direct sunlight, which may cause 

discoloration or malfunctions. 

 

 

Do not mix battery types, or new and old batteries. Replace 
with all new batteries at the same time. 

 

 

If the scale is not to be used for a long period of time, remove 
all batteries from the battery compartment to avoid leakage. 

 

 

Avoid overloading to the scale. 

 

 

Avoid using the weighing platform to move the scale, as that 
could cause damage to the scale.   

 

 

Avoid chemical solvents. Clean the scale with water. 

 

 

When the scale is used with an AC adapter, the scale does not 
conform to IP65 protection. 

 

IP65 
 
 
 
 

Degrees of protection against water: Protected against water jets. 
Degrees of protection against solid foreign objects: Dust-tight. 

I

nternational 

P

rotection of IEC529. 

Содержание SK-1000WP

Страница 1: ... 0 ふ SK 1000WP SK 2000WP SK 5000WP SK 5001WP SK 10KWP SK 20KWP SK 30KWP 1WM PD4000461B ...

Страница 2: ...ter for the scale Other adapters may cause damage AC adapter is optional Internal service or adjustment to this product should be performed by a qualified person CAUTION Avoid installing the scale in direct sunlight which may cause discoloration or malfunctions Do not mix battery types or new and old batteries Replace with all new batteries at the same time If the scale is not to be used for a lon...

Страница 3: ...RE ZERO key Sets display to zero or subtracts weight of a container Four leveling feet Battery cover Batteries are not included AC adapter socket STABLE indicator Indicates when the reading is stable Polarity NET indicator Indicates when NET weight is displayed Tare function is used ZERO indicator Indicates when the scale zero is correct Weighing unit Battery compartment Battery cover lock Battery...

Страница 4: ...r Optional CAUTION When using an AC adapter the scale doesn t comply with IP65 The AC input requirement could be 100 120 220 230 or 240 volts 50 60Hz depending on the area where used so please verify that the adapter is the correct type Plug the AC adapter to the AC adapter socket inside the battery compartment Setting up the Scale CAUTION Avoid installing the scale in direct sunlight that may cau...

Страница 5: ...ale Then the scale displays all segments for a few seconds and then 0 will be displayed 2 Start weighing If you do not use a container for weighing Press the RE ZERO key to display 0 Verify the reading is 0 Place objects on the weighing platform to weigh When the reading becomes stable the stable indicator is displayed If you use a container for weighing Place an empty container on the platform Wa...

Страница 6: ...20KWP 20kg 2g SK 30KWP 30kg 2g 1 Enter calibration mode Press the ON OFF key to turn the power off While pressing both the RE ZERO and UNITS keys press the ON OFF key Then Cal will be displayed 2 Zero calibration Press the RE ZERO key to calibrate zero Cal0 will be displayed When you have proceeded to the display other than Cal0 press the ON OFF key to turn the power off and start over again Wait ...

Страница 7: ...tion value 1 Enter calibration mode Press the ON OFF key to turn the power off While pressing both the RE ZERO and UNITS keys press the ON OFF key Then Cal will be displayed 2 Select a digit to be changed Press the UNITS key The previously set value for example 979 8 will be displayed A digit after the comma will be changed by pressing the RE ZERO key Press the UNITS key to move the comma and sele...

Страница 8: ... kg 6 4 lb 3 2 kg 7 1 lb Calibration weight 1000g 0 1g 2000g 0 2g 5000g 0 5g 5000g 0 5g 10kg 1g 20kg 2g 30kg 2g Accessories This manual Options AC adapter The Value of Gravity at Various Locations Amsterdam 9 813 m s2 Manila 9 784 m s2 Athens 9 807 m s2 Melbourne 9 800 m s2 Auckland NZ 9 799 m s2 Mexico City 9 779 m s2 Bangkok 9 783 m s2 Milan 9 806 m s2 Birmingham 9 813 m s2 New York 9 802 m s2 B...

Страница 9: ... 8 World Map ...

Страница 10: ...tschland Telefon 49 0 4102 459230 Telefax 49 0 4102 459231 A D Australasia Pty Ltd 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D KOREA Limited 한국에이 엔 디 주 대한민국 서울시 영등포구 여의도동 36 2 맨하탄 빌딩 8층 8th Floor Manhattan Bldg 36 2 Yoido dong Youngdeungpo ku Seoul KOR 전화 82 2 780 4101 팩스 82 2 782 4280 A D RUS CO LTD Компания ЭЙ энд ДИ РУС 121357 Российска...

Отзывы: