Keyboard Functions

NET

GROSS

ZERO

lb

kg

TARE

PRINT

SB-30/70/150 Series Keyboard

KEY

FUNCTION

ZERO

Sets scale to display "0" only when a) in Gross mode, b) not in overload and c) not in
motion.

NET

GROSS

Toggles between Gross and Net weight display if a tare has been established.

TARE

Used to establish the weight on the platform as the tare weight. You cannot establish
zero or negative gross weight as a tare. Also, the scale must not be in motion or in
overload.

lb

kg

Toggles between lb and kg units if enabled in the User (“A”) Menu.

PRINT

Sends "Print" data to serial port if scale is not in motion or in overload.

Содержание SB-30

Страница 1: ...S SB B S Se er ri ie es s D Di ig gi it ta al l B Be en nc ch h S Sc ca al le es s Instruction Manual Revision 1 3 April 5 2000 SB 30 SB 70 SB 150...

Страница 2: ...150 lb 70 kg capaci ties It comes standard with a bright LED screen for easy readout a removable stain less steel platform and an RS 232C serial communication port These scales can be configured to d...

Страница 3: ...e rocker switch to the ON 1 position The scale is now ready for use ON OFF SWITCH DC POWER JACK RS 232 PORT REMOTE DISPLAY ID TAG CALIBRATION SWITCH COVER SB 30 70 ONLY CONNECTOR SB 30 70 150 Back Pan...

Страница 4: ...never the displayed weight is within 0 25 divisions of true zero NET Indicates that the scale is displaying net weight GROSS Indicates that the scale is displaying gross weight TARE Indicates that the...

Страница 5: ...n NET GROSS Toggles between Gross and Net weight display if a tare has been established TARE Used to establish the weight on the platform as the tare weight You cannot establish zero or negative gross...

Страница 6: ...wer off to the unit 2 While holding down the lb kg key turn the power back on 3 When the display shows A1 the unit is in User Menu mode and you can release the lb kg key Shown at right are the direc t...

Страница 7: ...rial Data Format Selects the data format to be transmitted via the serial port to a printer or computer 0 Consolidated Controls Format 1 Toledo 8213 Format 2 A D NCI CAS Format 3 Transcell Technology...

Страница 8: ...tional and SET key assign ments SET SETUP MENU CHART F1 Display Mode F6 Zero Range F9 Calib Unit 0 1 F11 Display Check F12 Calibration Press ZERO key to begin Press ZERO key to begin 0 1 100 1 9 To pl...

Страница 9: ...ation Places scale into the calibration routine Scrolling down with the ZERO key one level begins the procedure Press ZERO key to begin sequence F13 Factory Reset This sub menu will reset all paramete...

Страница 10: ...ged by pressing the PRINT key or the TARE key 5 After setting the exact value press the NET GROSS key to save the value 6 If the calibration was successful the display will show ECAL momentarily then...

Страница 11: ...x 0 05 lb 0 70 x 0 02 kg CONSTRUCTION Base Steel and ABS Platform Stainless Steel Feet Non skid Hard Rubber DISPLAY 6 Digit 0 6 7 Segment Green LED OVER CAPACITY ANNUNCIATION 102 of Full Scale Capacit...

Страница 12: ...lect the proper settings for the following using the scale s settings Baud Rate Data Bits Parity Stop Bits 1 4 Enable the CAPS LOCK key on your PC 5 This test verifies that the scale is transmitting p...

Страница 13: ...ary Try re calibrating the scale if this doesn t solve the problem Otherwise possible load cell damage due to overloading LO Warmup Mode The scale has been turned on without the platter installed Inst...

Страница 14: ...uch goods by Seller discloses that the nonconformity actually exists and was not caused by accident misuse neglect alteration improper installation improper or un authorized repair or improper testing...

Отзывы: