A&D SB-30 Скачать руководство пользователя страница 2

2   

Revision 04/2001

ATTENTION:

To extend the life of your digital scale, do not drop items to be weighed onto the
platform or overload the scale beyond its rated capacity. Shock-loading and
overloading may damage the load cell and void the warranty.

Table of Contents

Introduction ..................................................................................................................................2
Installation and Wiring..................................................................................................................3
Display Overview..........................................................................................................................4
Keyboard Functions .....................................................................................................................5
User Menu Mode..........................................................................................................................6
Setup Menu Mode ........................................................................................................................7
Calibration ....................................................................................................................................9
APPENDIX A: Specifications .......................................................................................................11
APPENDIX B: Troubleshooting the Serial Port ............................................................................12
APPENDIX C: Displayed Error Codes .........................................................................................13
APPENDIX D: Warranty and Service Information........................................................................14

Introduction

The SB-30/70/150 Digital Bench Scales are
compact bench scales with display and five
function keyboard. It is available in 30 lb (15
kg), 70 lb (30 kg) and 150 lb (70 kg) capaci-
ties. It comes standard with a bright LED
screen for easy readout, a removable stain-
less steel platform, and an RS-232C serial
communication port.

These scales can be configured to display
their divisions in two separate modes – non-
NTEP mode and NTEP mode. The scale is
shipped from the factory configured in NTEP
mode. The NTEP mode is supplied for
scales which need to comply with Handbook

44 requirements. To re-configure the scale,
please refer to the “Setup Menu Mode” sec-
tion of the manual.

SB-30/70/150 use full duplex RS-232C serial
format for communication with personal
computers or remote displays. Units can
transmit data on demand or continuously in
several popular data protocols.

Each scale’s serial communication parame-
ters are altered through the User menu The
“User Menu Mode” section of the manual
explains how to use the five front panel keys
to maneuver and save settings in this menu.

Содержание SB-30

Страница 1: ...S SB B S Se er ri ie es s D Di ig gi it ta al l B Be en nc ch h S Sc ca al le es s Instruction Manual Revision 1 3 April 5 2000 SB 30 SB 70 SB 150...

Страница 2: ...150 lb 70 kg capaci ties It comes standard with a bright LED screen for easy readout a removable stain less steel platform and an RS 232C serial communication port These scales can be configured to d...

Страница 3: ...e rocker switch to the ON 1 position The scale is now ready for use ON OFF SWITCH DC POWER JACK RS 232 PORT REMOTE DISPLAY ID TAG CALIBRATION SWITCH COVER SB 30 70 ONLY CONNECTOR SB 30 70 150 Back Pan...

Страница 4: ...never the displayed weight is within 0 25 divisions of true zero NET Indicates that the scale is displaying net weight GROSS Indicates that the scale is displaying gross weight TARE Indicates that the...

Страница 5: ...n NET GROSS Toggles between Gross and Net weight display if a tare has been established TARE Used to establish the weight on the platform as the tare weight You cannot establish zero or negative gross...

Страница 6: ...wer off to the unit 2 While holding down the lb kg key turn the power back on 3 When the display shows A1 the unit is in User Menu mode and you can release the lb kg key Shown at right are the direc t...

Страница 7: ...rial Data Format Selects the data format to be transmitted via the serial port to a printer or computer 0 Consolidated Controls Format 1 Toledo 8213 Format 2 A D NCI CAS Format 3 Transcell Technology...

Страница 8: ...tional and SET key assign ments SET SETUP MENU CHART F1 Display Mode F6 Zero Range F9 Calib Unit 0 1 F11 Display Check F12 Calibration Press ZERO key to begin Press ZERO key to begin 0 1 100 1 9 To pl...

Страница 9: ...ation Places scale into the calibration routine Scrolling down with the ZERO key one level begins the procedure Press ZERO key to begin sequence F13 Factory Reset This sub menu will reset all paramete...

Страница 10: ...ged by pressing the PRINT key or the TARE key 5 After setting the exact value press the NET GROSS key to save the value 6 If the calibration was successful the display will show ECAL momentarily then...

Страница 11: ...x 0 05 lb 0 70 x 0 02 kg CONSTRUCTION Base Steel and ABS Platform Stainless Steel Feet Non skid Hard Rubber DISPLAY 6 Digit 0 6 7 Segment Green LED OVER CAPACITY ANNUNCIATION 102 of Full Scale Capacit...

Страница 12: ...lect the proper settings for the following using the scale s settings Baud Rate Data Bits Parity Stop Bits 1 4 Enable the CAPS LOCK key on your PC 5 This test verifies that the scale is transmitting p...

Страница 13: ...ary Try re calibrating the scale if this doesn t solve the problem Otherwise possible load cell damage due to overloading LO Warmup Mode The scale has been turned on without the platter installed Inst...

Страница 14: ...uch goods by Seller discloses that the nonconformity actually exists and was not caused by accident misuse neglect alteration improper installation improper or un authorized repair or improper testing...