Maximizing Money Count Performance

Environment

:  

The MC-2000 is calibrated & ready for use when unpacked.  Always follow

the instructions in “Getting Started” Section on page 2.

Money Count Accuracy

Silver Coins: nickels, dimes & quarters (loose or rolls) are no problem in any environment.

Pennies: difficult to guarantee because average piece weights vary greatly.  Our tests suggest
that you will typically be within 2 cents per 100.  Penny Roll accuracy is no problem.

Paper Currency:  $1s & $5s are the most difficult because they tend to circulate more fre-
quently, getting the most wear.  Also, 

all

 bills will absorb moisture from humidity or steam,

which adds weight that 

may

 reduce counting accuracy. The Factory setting of F10 restricts

placing more than 40 bills on the scale at one time to overcome the inconsistent weights of
paper money, hence maximizing accuracy.  This value of 40 can be altered to your personal
environment or completely disabled.  In ideal environments, it is not uncommon for the MC-
2000 to accurately count 100s of bills when placed on the scale all at once.  Although operating
speed is slightly increased, risk of innaccurate count is also increased.

Basic gram (g) and ounce (oz) Weighing Operation

1.  Press 

MODE

 to select unit of measure.

2.  Before weighing an item, make sure the scale shows a zero weight indication. If not, re-

move all items from the platter and press 

ZERO

 key.

3.  Place the item on the scale’s platter and allow the weight indication to stabilize.

4.  To add weight value to accumulator, press 

ADD

.  (Value also prints.)

5.  To display accumulator at any time (for 3 seconds), press 

TOTAL

.

6.  To clear accumulator and print total, press/hold 

ZERO

, then press 

TOTAL

.

Basic Counting (pcs) Operation

1.  Before weighing an item, make sure the scale shows a zero weight indication. If not, re-

move all items from the platter and press 

ZERO

 key.  If using a container, place empty

container on scale and press 

ZERO

.

2.  Press 

MODE

 until “5  0  pcs” is displayed.   To change sample size from 5 /10 / 20 / 50,

continue to press 

Sample

.

3.  Place selected number of samples on the scale platter and allow the weight indication to

stabilize.  “5 – pcs” is now displayed.  Press 

Enter

.  “5 pcs” is now displayed and you can

continue to count.  If “Lo” is displayed, sample size is too small and will advance to next
largest sample size.  Add additional samples to equal the value on the display.  Press

Enter

 again.

4.  To add count value to accumulator, press 

ADD

.  (Value also prints.)

5.  To display count accumulator at any time (for 3 seconds), press 

TOTAL

.

6.  To clear count accumulator and print total, press/hold 

ZERO

, then press 

TOTAL

.  To

determine a new APW, press 

MODE

.

Содержание MC-2000

Страница 1: ...M MC C 2 20 00 00 0 M Mo on ne ey y C Co ou un nt te er r E EP PR RO OM M V Ve er rs si io on n 2 2 6 6 Instruction Manual March 18 2001...

Страница 2: ...peration 5 Basic Counting PCS Operation 5 Error Codes 6 Setup Functions 6 To Access Function Settings 7 F1 Calibration 7 F2 Re initialize all Factory Settings F1 F6 8 F3 Auto Currency Advance 8 F4 Aut...

Страница 3: ...tra charge A coin scoop is provided with each scale and is necessary for the purpose of counting coins Optional AD 1191 Roll Printer provides an audit trail with individual quantity monetary value for...

Страница 4: ...00 Only used in Money mode ROLLS Selects coin ROLLS count Cycles from 1 5 10 25 1 Only used in Money mode ZERO Clear ZEROes anything on platform such as a container Used in all modes Press hold Clear...

Страница 5: ...stack until value displayed then continue Repeat for each bill de nomination no scoop 4 Count ROLLS Display shows 0 00 Ready to count ROLLS 1 5 10 25 1 Place 1 roll s on plat form then remove Repeat...

Страница 6: ...ghing Operation 1 Press MODE to select unit of measure 2 Before weighing an item make sure the scale shows a zero weight indication If not re move all items from the platter and press ZERO key 3 Place...

Страница 7: ...enomination as money removed from MC 2000 F4 OFF Auto Power Off If using AC adapter we recommend that you leave the scale on at all times If using batteries change F4 to ON MC 2000 will turn itself of...

Страница 8: ...els or bills then confirm the scale accuracy If you determine that the scale is light on all denominations you should recalibrate If you determine count is okay on most denominations but light on one...

Страница 9: ...er need to make any alterations see F10 for easiest adjustment of bill count accuracy Factory Settings COINS APW g 1 2 56480 5 4 96532 10 2 26986 25 5 64449 100 8 10000 BILLS APW g 1 0 99970 5 0 98196...

Страница 10: ...en shows Zero Place empty coins scoop or cup to be used then press ZERO Then press Enter to save To disable the tare entirely when display shows tA on press ROLLS display then shows tA off then press...

Страница 11: ...skid Hard Rubber DISPLAY 6 Character 7 Segment LCD 9 Annunciators KEYPAD 8 key Tactile Switch Type OVER CAPACITY ANNUNCIATION 102 of Full Scale Capacity POWER SOURCE AC Adapter 9 VDC 500 mA incl Batt...

Страница 12: ...period Two 2 years from date of shipment One year for AD 1191 Printer These war ranties are made upon the express condition that 1 Buyer notifies Seller of such non conformity with detailed explanatio...

Отзывы: