Introduction

The MC-2000 is a low-cost, easy to use, 5 lb. money counter and scale designed pri-
marily for counting out cash register drawers of US coins, bills & coin rolls.  Other fea-
tures include conventional counting of items other than coins, plus basic weighing in
grams and ounces.  When not counting money, use your MC-2000 to determine post-
age or count raffle tickets, literature, plastic or electronic parts, nuts & bolts, beads or
whatever you desire.

The MC-2000 is fast, accurate and 

very user-friendly

, prompting the operator through a cash

drawer count in the same typical fashion as hand counting: coins (1,5,10,25,$1), bills
(1,5,10,20,50,100) & coin rolls (1,5,10,25,$1).   A totalized value is available at any time by the
press of a button. The MC-2000 has user setup adjustments allowing customized site operation,
best suited for individual desires.  (see “F” settings in this manual.

Housed in a durable, compact gray-colored plastic enclosure, the MC-2000 is easy to store when
not in use. Six (6) AA alkaline battery operation allows for easy portability. An environmentally
friendly AC adapter is included at no extra charge.

A coin scoop is provided with each scale and is necessary for the purpose of counting coins.

Optional AD-1191 Roll Printer provides an audit trail with individual quantity & monetary value for
each coin & bill along with time, date & total.

Getting Started

After unpacking the scale, a small amount of assembly is required.  These instructions are extremely
important for maximizing accuracy & count performance!!!!!!

þ

 

Locate the platform and affix to the scale in the holes provided. Be sure to align the end marked
“FRONT” with the front of the scale.  Firmly squeeze the platter into place.

þ

 

Plug the enclosed AC Adapter into the MC-2000 first, then into an AC outlet.  (Or install 6 each al-
kaline batteries.)

þ

 

Place the MC-2000 on a firm and stable table, ensuring all leveling legs are firmly resting on your
counter.

þ

 

When using the AC adapter, we recommend that you leave power on continuously.

þ

 

Do not share an AC outlet with other noise producing products; i.e. anything with an electrical motor
or relay.

þ

 

Do not turn the scale ON with an object already on the platform.

þ

 

Do not operate the MC-2000...

...in an area with changing ambient temperature.

...in direct sunlight.

...in an area with high humidity.

...in a dusty environment.

...in a windy area.

...in an area with vibration.

þ

 

Review the “F’ settings explained in this manual to determine your most desired modes of opera-
tion.

Содержание MC-2000

Страница 1: ...M MC C 2 20 00 00 0 M Mo on ne ey y C Co ou un nt te er r E EP PR RO OM M V Ve er rs si io on n 2 2 6 6 Instruction Manual March 18 2001...

Страница 2: ...peration 5 Basic Counting PCS Operation 5 Error Codes 6 Setup Functions 6 To Access Function Settings 7 F1 Calibration 7 F2 Re initialize all Factory Settings F1 F6 8 F3 Auto Currency Advance 8 F4 Aut...

Страница 3: ...tra charge A coin scoop is provided with each scale and is necessary for the purpose of counting coins Optional AD 1191 Roll Printer provides an audit trail with individual quantity monetary value for...

Страница 4: ...00 Only used in Money mode ROLLS Selects coin ROLLS count Cycles from 1 5 10 25 1 Only used in Money mode ZERO Clear ZEROes anything on platform such as a container Used in all modes Press hold Clear...

Страница 5: ...stack until value displayed then continue Repeat for each bill de nomination no scoop 4 Count ROLLS Display shows 0 00 Ready to count ROLLS 1 5 10 25 1 Place 1 roll s on plat form then remove Repeat...

Страница 6: ...ghing Operation 1 Press MODE to select unit of measure 2 Before weighing an item make sure the scale shows a zero weight indication If not re move all items from the platter and press ZERO key 3 Place...

Страница 7: ...enomination as money removed from MC 2000 F4 OFF Auto Power Off If using AC adapter we recommend that you leave the scale on at all times If using batteries change F4 to ON MC 2000 will turn itself of...

Страница 8: ...els or bills then confirm the scale accuracy If you determine that the scale is light on all denominations you should recalibrate If you determine count is okay on most denominations but light on one...

Страница 9: ...er need to make any alterations see F10 for easiest adjustment of bill count accuracy Factory Settings COINS APW g 1 2 56480 5 4 96532 10 2 26986 25 5 64449 100 8 10000 BILLS APW g 1 0 99970 5 0 98196...

Страница 10: ...en shows Zero Place empty coins scoop or cup to be used then press ZERO Then press Enter to save To disable the tare entirely when display shows tA on press ROLLS display then shows tA off then press...

Страница 11: ...skid Hard Rubber DISPLAY 6 Character 7 Segment LCD 9 Annunciators KEYPAD 8 key Tactile Switch Type OVER CAPACITY ANNUNCIATION 102 of Full Scale Capacity POWER SOURCE AC Adapter 9 VDC 500 mA incl Batt...

Страница 12: ...period Two 2 years from date of shipment One year for AD 1191 Printer These war ranties are made upon the express condition that 1 Buyer notifies Seller of such non conformity with detailed explanatio...

Отзывы: