1. INTRODUCTION
This manual describes how the HR-AZ
/
HR-A
series balance works and how to get the most out of it
in terms of performance.
Read this manual thoroughly before using the balance and keep it at hand for future reference.
1-1 About This Manual
This manual consists of the following five parts:
Basic operation ........................ Describes precautions on handling the balance, balance
construction and basic balance operation.
Adapting to the environment.... Describes response adjustment and calibration.
Functions ................................. Describes various functions of the balance.
RS-232C serial interface.......... Describes the interface which transmits data and controls the balance.
Maintenance ............................ Describes maintenance, error codes, troubleshooting,
specifications and options.
1-2 Features
The HR-AZ series balance is equipped with an internal mass for one-touch calibration.
Casing construction, strong protection against dust and moisture.
Multiple weighing units with most of the common units used around the world.
Standard RS-232C serial interface to communicate with a computer and to output the Good
Laboratory Practice (GLP) / Good Manufacturing Practice (GMP) compliant report.
Statistical calculation mode to statistically calculate the weight data, and display or output the
sum, maximum, minimum, range (maximum-minimum), average, standard deviation and
coefficient of variation.
Comparator Indicators, displaying the comparison results.
Hold Function, provided for weighing a moving object such as an animal.
Breeze break, provided for better stability if drafts are present.
Underhook, provided for suspended weighing.
As options, the USB interface (HRA-02), the Ethernet interface (HRA-08) and the built-in
battery unit (HRA-09) are available.
Connecting the USB interface, by cable to a Windows computer, allows transmission of the weight
data to Excel or Word. The Ethernet interface allows connection of the balance to a personal
computer through a LAN. The battery unit allows use of the balance where a power source is not
available.
The AD-8920A remote display, that is sold separately, allows reading the weight value in a
place away from the balance.
The optional AD-1688 data logger provides easy weighing data management.
●
The optional AD-1687 weighing environment logger provides easy management of the
weighing data, such as environmental data for the weighing and so on.