2
1
INTRODUCTION
The AD-8922A is a remote controller. Read this manual completely before using the AD-8922A in order to
ensure a sufficient understanding for proper use.
1
-
1
Outline
The AD-8922A is connected to an A&D manufactured weighing instrument, using the RS-232C serial interface.
Displays the weighing data transmitted by the weighing instrument.
Key operations remotely control the weighing instrument.
(Entering the function setting mode of the weighing instrument is not available. Available operations
depend on the weighing instrument used. See Table 2 in "1-2 Applicable Instruments".)
The data the AD-8922A receives can be output, using the RS-232C serial interface. So, external
devices such as a personal computer or a printer can be connected to the AD-8922A.
Can be panel-mounted.
Various options such as BCD output, comparator output, current loop input and analog output are
available. For details, refer to "9 OPTIONS" and the following relevant chapters.
When connected to the AD-4212C, the AD-8922A can change the response characteristic, calibrate
the AD-4212C using the external weight, and both instruments can share power.
(Power can be supplied to both instruments by plugging the AC adapter into either the AD-4212C or
the AD-8922A. For details, refer to "3-3 Turning the Power on ".)
1
-
2
Applicable Instruments
Applicable weighing instruments and what is required are shown in the table below.
Table 1 Applicable weighing instruments and what is required
What is required to connect to
a weighing instrument
Cable required to connect to
an external device such as
Weighing
instrument
Option for the
instrument
Communications cable*
(Length 2 m)
Personal
computer
AD-8121B
compact printer
AD-4212C
None
(D-Sub 9-pin)
None
(Use the cable provided
for AD-4212C)
GX, GF, GX-K,
GF-K, GP, FP,
AD-4212A/B, GR, HR
None
(D-Sub 25-pin) AX-KO1710-200
EK-
i
, EW-
i
, FC-
i
,
FC-S
i
, GH, HR-
i
,
FZ-
i
, FX-
i
None
(D-Sub 9-pin)
AX-KO2466-200
EK-G, EK-H,
ET-W, EW-G
OP-03
(D-Sub 25-pin) AX-KO1710-200
HV-G, HV-WP,
HW-G, HW-WP
None
(DIN 7-pin)
AX-KO1786-200
FG
OP-03
(DIN 7-pin)
AX-KO1786-200
FS, FS-KL
OP-03
(DIN 8-pin)
AX-KO1786-200
FG-L, FG-M
OP-23
(DIN 8-pin)
AX-KO1786-200
AX-KO1786-200
AX-KO462-200
Note (*) - The standard communications cable is AX-KO1710-200. A substitute communications
cable may be provided as specified when ordering the AD-8922A.
- When connecting to the AD-4212C, use the AX-KO3590-500 (5m) cable, provided as standard
for the AD-4212C.