3-8
IMBA-H110A
Target Temperature [50]
Input value range: [0~127]
Tolerance of Temperature [0]
Input value range: [0~7]
Fan Out Start-Up Value [127]
Input value range: [0~255]
Fan Stop Duty [To Fan Out Stop Value]
Configuration options: [Down to 0] [To Fan Out Stop Value]
Fan Out Stop Value [100]
The Fan Out value decreases to this value if the temperature reaches below
the lowest temperature limit. Input value range: [0~255]
Fan Out Stop Time [60]
Determines the amount of time it takes for the Fan Out value to fall from the
stop value to zero. Input value range: [0~255]
Critical Temperature [75]
Determines the amount of time Fan Out takes to decrease its value by one
step. Input value range: [0~255]
Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to increase its value by one
step. Input value range: [0~255]
Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to decrease its value by one
step in intervals of 0.1 seconds. Input value range: [0~255]
The following items appear only when you set
Fan Control Mode
to [Speed
Cruise Mode].
Target Speed [0]
Input value range: [0~4096]
Speed Tolerance [2]
Input value range: [0~64]
Fan Out Step Up Time [10]
Input value range: [0~255]
Fan Out Step Down Time [10]
Input value range: [0~255]
E13195_IMBA-H110A_Guide.indb 8
2017/9/25 14:05:16
Содержание IMBA-H110A
Страница 1: ...Industrial Motherboard IMBA H110A E13195_IMBA H110A_Guide indb 1 2017 9 25 14 05 08...
Страница 8: ...IMBA H110A 1 4 E13195_IMBA H110A_Guide indb 4 2017 9 25 14 05 08...
Страница 16: ...IMBA H110A 2 8 A B C 4 5 E13195_IMBA H110A_Guide indb 8 2017 9 25 14 05 11...
Страница 44: ...3 14 IMBA H110A E13195_IMBA H110A_Guide indb 14 2017 9 25 14 05 16...