EmbeddedBlue 500
81
Copyright ©2003 A7 Engineering, Inc.
Set Link Timeout
The
set link timeout
command sets the amount of time it takes for the local eb500
module to notice that the connection has been broken, if the remote device
disappears. This timeout also has an effect on how robust the communications link is
to interference. If this value is set very low, the link may be lost if interference picks
up for several seconds, such as when a heavy burst of 802.11 traffic is encountered.
In Bluetooth terminology, this command controls the setting for link supervisor
timeout.
Syntax
set
linktimeout timeout [*]<CR>
Parameters
timeout
The time it takes for the eb500 to notice that a connection has
been broken. The default value is 5. The maximum value is 40
seconds.
*
An optional parameter used to persist the new setting when
the module is powered down.
Example
>set linktimeout 10<CR>
ACK<CR>
>