2
Important Safety Information
READ AND FOLLOW ALL INSTRUCTIONS
• Read this manual completely before attempting installation and/or operation.
• Install in accordance with the installation instructions.
• Connect to a grounded, grounding type receptacle only.
• Follow all applicable electrical codes.
• To avoid electric shock, be sure to turn power OFF and disconnect from power source
before any service work is performed. Failure to do so could result in serious injury or
death. Have a licensed electrician make all electrical connections. Replace damaged
electrical cables immediately.
• Install the ozone generator at least five feet from water using nonmetallic plumbing.
• The SP-5G must be mounted indoors or under a cover for protection from the elements.
• Install check valves to prevent water from coming into contact with the electrical equipment.
• The electrical supply for this product must include a suitably rated switch or circuit breaker
to open all ungrounded supply conductors.
• Keep ambient temperature around the equipment between 40° and 100° Fahrenheit
(4.5° to 38° Celsius). If installing the equipment in an environment with temperatures over
100° Fahrenheit, provide additional air cooling. Installation without additional air cooling
in an environment where temperatures exceed 100° Fahrenheit for any continuous 24-
hour period will void the warranty.
• If feeding ozone generator with an oxygen supply, a spontaneous and violent ignition may
occur if oil, grease or greasy substances come in contact with oxygen under pressure.
These substances must be kept away from oxygen regulators, cylinder valves, tubing,
connections, and all other oxygen equipment.
CAUTION!
In case of accidental leakage, install the ozone generator in a well-ventilated area.
In accordance with California Regulations, this ozone generator is solely for
industrial use and must be installed by a professional. Potential health hazard:
emits ozone.
Содержание SP-5G
Страница 6: ...5 1 2 3 4 5 6...