8
Main Power
• Use the power cable provided to connect the SP-3G (220V) Ozone Generator to a properly
rated and grounded receptacle.
• A ground fault circuit interrupter must protect the circuit if the ozone generator will be
used where water is present.
Tube Connection and Start Up
• Connect a silicone tube (if using an oxygen generator, oxygen tank or external air
compressor) to the SP-3G (220V) Ozone Generator (Air In). This will serve as oxygen or air
for ozone production. (2-4 LPM @ 2 PSI maximum.)
• Connect the ozone generator PTFE tube (Ozone Out) to the application processor.
• Install a check valve 10 inches after the ozone outlet tube fitting. Install the check valve
by cutting the tube ten inches after ozone out fitting. Next, connect both ends of the cut
tubes to the check valve. Please direct the arrow on the check valve toward the . NOTE:
The venturi injector has an internal check valve to help prevent backflow.
• Make sure there is a vacuum (or that there is suction) at the opening via a gauge or test
it by putting your finger on the opening.
• There will be a small suction at this opening. The suction will move the ozone out of the
SP-3G (220V) Ozone Generator and inject it into the piping system.
• Check that the flow meter indicates that the air flow is at least 2-4 LPM.
• Now connect the PTFE tube from the application processor venturi injector to the ozone
generator.
• Turn on the power on the external panel of the ozone generator.
• The ozone indicator light should illuminate and the unit’s fan should turn on.
• Increase power to the cells by turning the ozone control knob clockwise.