Troubleshooting
The test method for failure of the ozone generator:
• Check the power input for correct voltage (220V)
• If the ozone generator is on, but not producing ozone, then the SP-3G (220V) Ozone
Generator is overheating or there is backflow to the ozone generator.
• Turn off the ozone generator and let the air flow through the unit for 1 to 2 hours to dry
the ozone tube.
• Check the main fuse. Change it if needed. It is a 3 AMP for this unit.
• Check the tubing inside the machine for kinks.
• If the machine can produce some air, but the air is not ozone; please check the following:
• The power indication lamp is lit.
• Check the ozone control knob is set above zero.
• Check the ozone board fuse.
• Check the wire from terminal to ozone board.
• Check that the potentiometer wire is connected to the ozone board.
If you are still experiencing problems, please contact A2Z Ozone at 1+ (502) 499-4977.