![A2Z Ozone SP-3G Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/a2z-ozone/sp-3g/sp-3g_operating-manual_448115010.webp)
Maintenance
Clean Air Filter
This filter must be cleaned regularly. Depending on the location of the SP-3G (220V) Ozone
Generator, it may be necessary to clean the air filter monthly. The filter elements are located
on the bottom of the cabinet. This is the air intake element for the cooling fan, so it requires
more frequent cleaning. Clean the element with soap and water, rinse, and dry completely
before reinstalling. Clean this filter regularly. Failure to do so will promote overheating and
void the warranty.
NOTE
: In a clean environment, perform the cleaning procedure every three months.
• Turn the SP-3G (220V) Ozone Generator off
• Clean the filter screen with soap and water
• Rinse
• Dry the filter with a clean towel
• Install the screen back onto the unit
• Turn the ozone generator on
• NOTE: Be sure the SP-3G (220V) Ozone Generator’s screen does not touch fan blade
CAUTION
: There is extremely high voltage inside the ozone generator. If you suspect a problem,
disconnect the power to the SP-3G (220V) Ozone Generator at the service disconnect box
or main electrical panel and immediately contact your maintenance technician. Inspect the
ozone delivery line check valves daily for damage and replace the check valve every 6 months
to a year.
9
Содержание SP-3G