![A2Z Ozone MP-3000 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/a2z-ozone/mp-3000/mp-3000_operating-manual_3162598008.webp)
7
Installation Instructions
Ozone Generator Placement
• Install ozone generator in a clean, dry area with good ventilation.
• The MP-3000 (110V) Ozone Generator should be placed above any water tank level.
• If pressure is lost in the venturi injector vacuum and the unit is below water tank level,
gravity will cause water to travel down the ozone output hose and enter into the ozone
generator.
• Place stone no more than 18 inches deep.
NOTE:
Place the ozone generator in room temperatures below 130° F, 54 ° C. Prolonged
exposure to extreme temperatures will void the warranty.
Venturi Installation
• Install the venturi injector with the bypass valve on water recirculation pipeline.
• Point the arrow on venturi injector in the same direction as the water flow.
• Turn water pump on and close the bypass valve until a vacuum is created at the venturi
injector input.
NOTE:
Use a gauge to check vacuum -2 to -3 PSI (-0.14 to -0.21 bars) or place finger over end
of venturi injector valve to feel the vacuum. At this point, the air is injected into the waterline.
This can be observed as air bubbles inside the water tank.
NOTE:
The water tank requires an exhaust to the outside of the building with ozone destructor
to remove excessive ozone.
Main Power
• Use the power cable provided to connect the MP-3000 (110V ) Ozone Generator to a
properly rated and grounded receptacle.
• If the MP-3000 will be used where water is present, a ground fault circuit
interrupter must protect the circuit.