
14
The test method for failure of the MP Series:
• Check the power input for correct voltage (110V).
• If the unit is on but no ozone is being produced, this could be due to:
• Overheating of the unit
• Water back flow to the ozone generator
• Turn off ozone generator and let air flow through the unit for five to ten minutes.
• Check the fuse, change if needed.
• The MP-3000 uses a 3 AMP fuse for the back rocker switch and a 5 AMP fuse in the
ozone board.
• Check the air compressor line or oxygen input
• If the generator is taking in oxygen, please check the tube inside the machine for kinks.
• If the machine can produce some air, but the air is not ozone please check the following:
• The ozone power indication lamp is lit
• Check ozone control knob is set above 20%
If you are still experiencing problems, please contact A2Z Ozone at (502) 499-4977 or
[email protected] for more information.
1
Main Power
Switch
Powers the whole unit. If there is no power to the unit, check here
first.
2
Main Fuse
If no power to the unit, check the Main Power Switch first, then
check this fuse.
3
Spare Fuse
Holds spare 3A fuse.
Содержание MP-3000
Страница 6: ...5 1 2 3 4 5 6 7 8 9 MP 3000...
Страница 14: ...13 1 2 3...