10
• Please direct the arrow on the check valve toward the venturi injector.
• Turn the oxygen generator ON first and then the ozone ON switch (
O
3
Switch
). The air pump
stays OFF.
• Turn timer knob clockwise to the amount of time needed.
• To run continually, turn the timer knob counterclockwise.
• The ozone light and fan will turn on.
• Increase power to the cells by turning the ozone control knob clockwise.
• Prior to shutting off the oxygen generator feed gas to the MP-3000 (110V) Ozone Generator,
first turn off the ozone generator switch and allow the unit to purge with oxygen for about
1 minute.
• Then, turn off the oxygen generator.
Using Internal Air Compressor:
This unit comes with a small air compressor built
inside the ozone generator
• Connect the air out of the unit with the
O
2
In using the supplied oxygen tubing, located on
the front panel on the ozone generator side.
• Connect ozone generator (Ozone Out) to the venturi injector.
• Install a check valve 10 inches after ozone outlet tube fitting.
• You may do this by cutting the tube ten inches after ozone outlet fitting.
• Connect both ends of cut tubes to the check valve.
• Please direct the arrow on the check valve toward the venturi injector.
• Turn ON/OFF both the main power and air compressor switch located on the front panel.
• To power down, flip the ozone switch and wait 30 seconds. Then flip the air pump switch.
Using External Air Compressor:
• Install air dryer after the air compressor. Use an oil-less air compressor only.
• Connect air dryer outlet to ozone generator (Oxygen In).
• Set air inflow rate at 2-4 liters per minute.
• Connect ozone generator (Ozone Out) to venturi injector.
• Install a check valve 10 inches after ozone outlet tube fitting. This can be done by cutting
a tube ten inches after ozone outlet fitting.
• Connect both ends of cut tubes to the check valve. Please direct the arrow on the check
valve toward venturi injector.
• Turn ON/OFF main power and air compressor switch at the same time. To turn off, flip off
the ozone power switch and wait 30 seconds. Then turn off external air pump.
NOTE:
Do not turn ON the air compressor switch on the front panel when using oxygen
generator, oxygen bottle or tank.