Aqua-6 Features
1
Light
Indicates when the unit is running. When it is in operation, the
light will remain a solid red.
2
On/Off Button
Use to turn the unit on and off. When on, the red light will
illuminate.
3
Pause Button
Use to pause the unit when it is in operation. The LCD will hold
the previously selected function and the time remaining until the
Pause Button is pressed again.
4
LCD Screen
Displays function setting selected and operation time remaining
after the Aqua-6 begins producing ozone. The ozone production
will start 10 seconds after the selection is made on the LCD.
5
Minus (-) Button
Use to select desired function setting from the Timer Function
table. The Minus Button will move the Function number down
sequentially.
6
Plus (+) Button
Use to select desired function setting from the Timer Function
table.
7
Tube Input
Where the PTFE tubing is attached to the unit. One end of the
ozone supply tubing is attached to the ozone outlet on the Aqua-6
unit, while the other end is attached to a diffuser stone.
8
Power Cord
Where the electrical cord is attached to the unit. Wait for the air
compressor to automatically shut off after each function before
unplugging the unit.