Operating Instructions
• Plug the Aqua-6 into an electrical outlet.
• Attach one end of the ozone supply tubing (36-inches long) into the ozone outlet at the
bottom of the generator and attach a diffuser stone onto the other end of the tube.
• Extend the tubing so that the diffuser stone and the Aqua-6 are as far apart
as possible.
• Push in the main power switch located on the face of the unit to the ON position.
• The red light above the main power button will illuminate.
• The LED will indicate 00 while blinking.
• Use the plus (+) and minus (-) buttons to select the function setting from the table on
page 6 for desired application time.
• Operating times will vary according to the size of the room or amount of water
being treated.
• The Aqua-6 will start 10 seconds after a setting is selected on the LED screen.
• Once the generator starts producing ozone, the LED changes to display the time
remaining for the setting you have chosen.
• Once the cycle is complete, the LED screen will change back to the setting number for
one-time run settings.
• Once a repeat cycle is complete, the LED screen will show the count down until the next
cycle.
• Remember, settings 1 through 5 are a one-time run setting.
• Settings 6 through 10 continuously repeat the cycle every hour.
• Settings 11 through 15 continuously repeat every 4 hours.
• To pause a setting, simply press the pause button below the LED screen.
• The LED will hold the previously selected function and the time remaining until the
pause button is pressed again.
• Press the plus (+) or minus (–) buttons to select another function if desired.
• Keep in mind, only run another function on the Aqua-6 after a cooldown cycle. This unit
is not made for continuous use.
• Repeat cycles will include a cooldown cycle in the operation of the unit.
• After the function is complete, the air compressor will run for 10 seconds and then
automatically shut off.
• Please allow the air compressor to shut off and then unplug or cut power to the unit.
7